EUVIMEDEUVIMED entdecken
Open Access

Raman Spectroscopy for Differentiating High‐ and Low‐Grade Canine Cutaneous Mast Cell Tumours

José Catarino iD, Susana Silva, Susana Novais, Joana Santos, Rita Payan-Carreira iD, Pedro Faísca iD, Joana Reis

Veterinary and Comparative Oncology · 2026-09 · 24 (3) · 621-630

DOI: 10.1111/vco.70083 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary and Comparative Oncology, online erschienen am 23.06.2026. Verfasst von José Catarino und 6 weiteren Autor:innen. Beteiligte Einrichtung: I-MVet, Faculdade de Medicina Veterinária, Universidade Lusófona-Centro Universitário de Lisboa, Lisboa, Portugal. Hauptthemen laut MEDLINE: Dog Diseases, Spectrum Analysis, Raman, Skin Neoplasms, Mastocytosis, Cutaneous. Die Arbeit nennt 65 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: National Funds through Portuguese Funding Agency, FCT-Fundacão Para a Ciência e a Tecnologia, Foundation for Science and Technology (FCT), Portugal.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Canine cutaneous mast cell tumours (MCTs) demonstrate variable clinical behaviour. Histological grading remains the primary prognostic approach, but some low‐grade tumours behave aggressively, and interobserver variability persists. This underscores the need for complementary and objective biomarkers. Raman spectroscopy (RS) is a non‐destructive optical technique based on the inelastic scattering of monochromatic light capable of detecting subtle biochemical changes in tissues. This exploratory study evaluates whether RS could differentiate low‐grade from high‐grade cutaneous MCTs based on characteristic vibrational signatures. Eighteen canine cutaneous mast cell tumours were graded according to the Kiupel two‐tier system, comprising 10 low‐grade and 8 high‐grade cases. Formalin‐fixed tumour samples were analysed, yielding a total of 68 Raman spectra. Spectra were acquired with a 785 nm laser, pre‐processed using baseline correction, and normalized to the 1007 cm −1 phenylalanine band. Data normality was tested with the Shapiro–Wilk test, and group comparisons used the Mann–Whitney U test ( α = 0.05). The 1007 cm −1 band showed no significant difference between Low‐ and High‐Grade tumours ( p = 0.068), validating its use for normalization. Conversely, the 860 cm −1 tyrosine‐associated band was significantly higher in high‐grade tumours ( p = 0.033). Ratios normalized to the 1007 cm −1 peak consistently discriminated between grades, with significantly higher values in low‐grade tumours across multiple spectral regions—particularly 1007/1299 and 1007/1301–1320 (all p < 0.05). Overall, RS identified distinct biochemical fingerprints between tumour grades in canine cutaneous MCTs, especially in spectral regions associated with amino acids, lipids, and nucleic acids. These findings support the potential of RS as a complementary tool for MCT characterization and encourage further validation in larger cohorts with clinical outcome data.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dog DiseasesSpectrum Analysis, RamanSkin NeoplasmsMastocytosis, CutaneousAnimalsDogsNeoplasm GradingFemaleMale

Stichwörter der Autor:innen

Raman spectroscopycaninemast cell tumoursoncology

Autor:innen und Institutionen

  • I-MVet, Faculdade de Medicina Veterinária, Universidade Lusófona-Centro Universitário de Lisboa, Lisboa, Portugal.
  • Comprehensive Health Research Centre (CHRC) & Departamento de Medicina Veterinária, Escola de Ciência e Tecnologia, Universidade de Évora, Évora, Portugal.
  • IPLUSO, Instituto Politécnico da Lusofonia, Lisboa, Portugal.
  • DNAtech, Laboratório Veterinário, Lisboa, Portugal.
  • INESC TEC Instituto de Engenharia de Sistemas e Computadores Tecnologia e Ciência, Porto, Portugal.
  • Departamento de Medicina Veterinária, Escola de Ciências e Tecnologia, Universidade de Évora, Évora, Portugal.

ORCID-Profile: José Catarino, Rita Payan-Carreira, Pedro Faísca

Förderung

  • National Funds through Portuguese Funding Agency, FCT-Fundacão Para a Ciência e a Tecnologia
  • Foundation for Science and Technology (FCT), Portugal

Zitieren

APA

Catarino, J., Silva, S., Novais, S., Santos, J., Payan-Carreira, R., Faísca, P., & Reis, J. (2026). Raman Spectroscopy for Differentiating High‐ and Low‐Grade Canine Cutaneous Mast Cell Tumours. Veterinary and Comparative Oncology, 24(3), 621-630. https://doi.org/10.1111/vco.70083

Vancouver

Catarino J, Silva S, Novais S, Santos J, Payan-Carreira R, Faísca P, et al. Raman Spectroscopy for Differentiating High‐ and Low‐Grade Canine Cutaneous Mast Cell Tumours. Veterinary and Comparative Oncology. 2026;24(3):621-630. doi:10.1111/vco.70083

BibTeX
@article{Catarino2026,
  author = {Catarino, José and Silva, Susana and Novais, Susana and Santos, Joana and Payan-Carreira, Rita and Faísca, Pedro and Reis, Joana},
  title = {Raman Spectroscopy for Differentiating High‐ and Low‐Grade Canine Cutaneous Mast Cell Tumours},
  journal = {Veterinary and Comparative Oncology},
  year = {2026},
  volume = {24},
  number = {3},
  pages = {621--630},
  doi = {10.1111/vco.70083}
}
Kostenlos starten →