SHINE – Validation of Near Infrared Fluorescence Lymphography Against Lymphoscintigraphy for Sentinel Lymph Node Biopsy in Dogs With Mast Cell Tumours
Veterinary and Comparative Oncology · 2025
DOI: 10.1111/vco.13058 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Veterinary and Comparative Oncology, 2025. Verfasst von L E Chiti und 4 weiteren Autor:innen. Beteiligte Einrichtung: Clinic for Small Animal Surgery, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland. Hauptthemen laut MEDLINE: Lymphoscintigraphy, Sentinel Lymph Node Biopsy, Dog Diseases, Lymphography. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 50 Literaturangaben. Gefördert von: UZH Postdoc Grant, Albert-Heim-Stiftung für Kleintiere, Stiftung für Kleintiere.
Abstract (Originalsprache)
Lymphoscintigraphy is the gold standard among sentinel lymph node (SLN) mapping techniques. Unfortunately, lymphoscintigraphy is not readily accessible, leading to the need for validation of alternative techniques. The aim of this study is to compare near‐infrared fluorescence lymphography (NIRF‐L) with lymphoscintigraphy for SLN resection in MCT and assess the impact of intraoperative NIRF guidance. Forty‐eight dogs with 60 MCT were included in this prospective, blinded, randomised controlled trial. Dogs underwent preoperative lymphoscintigraphy and were then randomised into two groups: in the treatment group ( n = 30) intraoperative NIRF‐L was performed; in the control group ( n = 30) no intraoperative guidance was implemented. Detection rate, concordance, sensitivity, and negative predictive values were recorded for NIRF‐L and lymphoscintigraphy. Surgical time and length of surgical incision were compared between treatment and control groups with the Wilcoxon test (5% significance). Detection rate was 100% for NIRF‐L and 98% for lymphoscintigraphy. Discordance occurred in one case. Sensitivity of NIRF‐L was 93.7% (95% C.I. 74.3%–99.3%) and negative predictive value ranged between 91.1% and 98.6% with a prevalence of nodal metastases of 61% and 18%. Based on the overlapping of the confidence intervals, NIRF‐L was not statistically different to lymphoscintigraphy for sensitivity. Lymphadenectomy was unsuccessful in 4/30 (13%) cases in the control group. Surgical time and incision were significantly shorter in the treatment group ( p < 0.001; p = 0.001). Based on our results, NIRF‐L is a valid alternative to lymphoscintigraphy for SLN removal in MCT. Moreover, it improves the success of lymphadenectomy, reduces surgical time, and incision length compared to an unguided technique.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Clinic for Small Animal Surgery, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland.
- Clinic of Diagnostic Imagining, Vetsuisse Factulty, University of Zurich, Zurich, Switzerland.
- Section of Veterinary Epidemiology, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland.
ORCID-Profile: L E Chiti
Förderung
- UZH Postdoc Grant
- Albert-Heim-Stiftung für Kleintiere
- Stiftung für Kleintiere
Zitieren
APA
Chiti, L. E., Beer, P., Ohlerth, S. M., Hartnack, S., & Nolff, M. C. (2025). SHINE – Validation of Near Infrared Fluorescence Lymphography Against Lymphoscintigraphy for Sentinel Lymph Node Biopsy in Dogs With Mast Cell Tumours. Veterinary and Comparative Oncology. https://doi.org/10.1111/vco.13058
Vancouver
Chiti LE, Beer P, Ohlerth SM, Hartnack S, Nolff MC. SHINE – Validation of Near Infrared Fluorescence Lymphography Against Lymphoscintigraphy for Sentinel Lymph Node Biopsy in Dogs With Mast Cell Tumours. Veterinary and Comparative Oncology. 2025. doi:10.1111/vco.13058
BibTeX
@article{Chiti2025,
author = {Chiti, L E and Beer, P and Ohlerth, S M and Hartnack, S and Nolff, M C},
title = {SHINE – Validation of Near Infrared Fluorescence Lymphography Against Lymphoscintigraphy for Sentinel Lymph Node Biopsy in Dogs With Mast Cell Tumours},
journal = {Veterinary and Comparative Oncology},
year = {2025},
doi = {10.1111/vco.13058}
}
EUVIMED