EUVIMEDEUVIMED entdecken
Fallbericht

Emergency whole‐tank transfer of cord blood units after cryogenic failure: A safe rescue strategy

Jesus Fernandez-Sojo iD, Carmen Azqueta, Nerea Castillo-Flores, Mònica Linares, Elena Valdivia, Laura Medina-Boronat, Sergio Arteaga, Nuria Rubio, Sonia Poyatos, Alexander Guterres, Ana Garcia-Buendia, Sergi Querol iD und 1 weitere

Transfusion · 2026

DOI: 10.1111/trf.70330 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Transfusion, 2026. Verfasst von Jesus Fernandez-Sojo und 12 weiteren Autor:innen. Beteiligte Einrichtung: Banc de Sang i Teixits, Barcelona, Spain. Hauptthemen laut MEDLINE: Fetal Blood, Cryopreservation, Blood Preservation. Die Arbeit nennt 11 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Cryogenic storage of cord blood units (CBUs) is critical to ensure long‐term viability and safety. Loss of vacuum in liquid nitrogen (LN 2 ) tanks is an exceptionally rare but high‐risk event that may lead to accelerated LN 2 evaporation and potential warming of stored units. Case Report We describe an emergency rescue transfer following suspected vacuum loss in a BioArchive cryogenic tank at a public cord blood bank. The tank contained 2880 CBUs, including 14 directed units. Progressive LN 2 consumption suggested structural failure, and in situ repair was not feasible. A rapid transfer procedure using a backup BioArchive‐compatible tank was performed with the assistance of the manufacturer. The maneuver involved crane‐assisted repositioning of the tank under the robotic system and was completed in 40 s. Continuous temperature monitoring confirmed stable vapor‐phase conditions throughout the procedure. Six CBUs stored in upper tank positions (worst‐case exposure) were evaluated post‐thaw. Cell recovery, viability, and clonogenic capacity were preserved and met release criteria for transplantation.

Conclusion

Emergency transfer of CBUs during cryogenic tank malfunction is feasible and can be performed safely without compromising product quality when executed under controlled conditions. This report provides practical guidance for managing rare but critical storage failures in cord blood banking using BioArchive system.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fetal BloodCryopreservationBlood PreservationHumansBlood Banks

Autor:innen und Institutionen

  • Banc de Sang i Teixits, Barcelona, Spain.
  • Instituto de Investigación Sanitaria, Hospital Universitari Vall d'Hebron, Barcelona, Spain.
  • Concessus, Sintra, Portugal.
  • REDMO (Spanish Bone Marrow Donor Registry), Fundació Josep Carreras, Barcelona, Spain.

ORCID-Profile: Jesus Fernandez-Sojo, Sergi Querol

Zitieren

APA

Fernandez-Sojo, J., Azqueta, C., Castillo-Flores, N., Linares, M., Valdivia, E., Medina-Boronat, L., Arteaga, S., Rubio, N., Poyatos, S., Guterres, A., Garcia-Buendia, A., Querol, S., & Grifols, J. R. (2026). Emergency whole‐tank transfer of cord blood units after cryogenic failure: A safe rescue strategy. Transfusion. https://doi.org/10.1111/trf.70330

Vancouver

Fernandez-Sojo J, Azqueta C, Castillo-Flores N, Linares M, Valdivia E, Medina-Boronat L, et al. Emergency whole‐tank transfer of cord blood units after cryogenic failure: A safe rescue strategy. Transfusion. 2026. doi:10.1111/trf.70330

BibTeX
@article{FernandezSojo2026,
  author = {Fernandez-Sojo, Jesus and Azqueta, Carmen and Castillo-Flores, Nerea and Linares, Mònica and Valdivia, Elena and Medina-Boronat, Laura and Arteaga, Sergio and Rubio, Nuria and Poyatos, Sonia and Guterres, Alexander and Garcia-Buendia, Ana and Querol, Sergi and Grifols, Joan R},
  title = {Emergency whole‐tank transfer of cord blood units after cryogenic failure: A safe rescue strategy},
  journal = {Transfusion},
  year = {2026},
  doi = {10.1111/trf.70330}
}
Kostenlos starten →