Multi‐center development and validation of a standardized protocol for biotinylated red blood cell analysis
Transfusion · 2026-05 · 66 (5) · 923-932
DOI: 10.1111/trf.70157 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Transfusion, online erschienen am 06.03.2026. Verfasst von Susanne Marschner und 12 weiteren Autor:innen. Beteiligte Einrichtung: Vitalant Research Institute, Denver, Colorado, USA. Hauptthemen laut MEDLINE: Erythrocytes, Biotinylation, Flow Cytometry. Die Arbeit nennt 40 Literaturangaben. Gefördert von: Biomedical Advanced Research and Development Authority.
Abstract (Originalsprache)
Background
Twenty‐four‐hour post‐transfusion recovery (PTR24) is a key measure of red blood cell (RBC) quality. Traditionally assessed using radioactive chromium‐51 ( 51 Cr), supply and facility limitations have prompted the need for alternatives. Biotinylation of RBCs (BioRBCs) offers a non‐radioactive method capable of distinguishing multiple RBC populations by flow cytometry. Researchers at three major blood centers developed a standardized BioRBC labeling protocol for pharmacokinetic studies. Study Design and Methods The multicenter development of the standardized protocol followed a two‐phase design. First, inter‐ and intra‐site flow cytometry variability was assessed using RBCs biotinylated at 6 and 18 μg/mL. Samples were stained with streptavidin‐phycoerythrin (SA‐PE), diluted, and analyzed in triplicates using shared flow cytometry templates. Second, inter‐site variability of biotinylation was tested using paired RBC units split and processed simultaneously at each site. Separation index (SI) was calculated as: SI = (median BioRBC − median unlabeled)/(84th percentile unlabeled − median unlabeled)/0.995.
Results
Staining and analysis of BioRBCs demonstrated minimal inter‐ and intra‐site variability when using identical protocols. Coefficients of variation for median fluorescence intensity were
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Vitalant Research Institute, Denver, Colorado, USA.
- Hoxworth Blood Center, University of Cincinnati, Cincinnati, Ohio, USA.
- American Red Cross Biomedical Services, Medical and Scientific Office, Washington, DC, USA.
- Dana Farber Cancer Institute, Harvard Medical School, Massachusetts, USA.
ORCID-Profile: Susanne Marschner, Bethany Brown, Zohreh Tatari-Calderone
Förderung
- Biomedical Advanced Research and Development Authority
Zitieren
APA
Marschner, S., Lee, D., Rugg, N., Brown, B., Nestheide, S., Wellington, M., Kanias, T., Tatari-Calderone, Z., Bhujbal, R., Finlon, J., Rahman, M., Cancelas, J. A., & HOXVITARC group (2026). Multi‐center development and validation of a standardized protocol for biotinylated red blood cell analysis. Transfusion, 66(5), 923-932. https://doi.org/10.1111/trf.70157
Vancouver
Marschner S, Lee D, Rugg N, Brown B, Nestheide S, Wellington M, et al. Multi‐center development and validation of a standardized protocol for biotinylated red blood cell analysis. Transfusion. 2026;66(5):923-932. doi:10.1111/trf.70157
BibTeX
@article{Marschner2026,
author = {Marschner, Susanne and Lee, Deborah and Rugg, Neeta and Brown, Bethany and Nestheide, Shawnagay and Wellington, Michael and Kanias, Tamir and Tatari-Calderone, Zohreh and Bhujbal, Richa and Finlon, Jeff and Rahman, Maria and Cancelas, Jose A and HOXVITARC group, HOXVITARC group},
title = {Multi‐center development and validation of a standardized protocol for biotinylated red blood cell analysis},
journal = {Transfusion},
year = {2026},
volume = {66},
number = {5},
pages = {923--932},
doi = {10.1111/trf.70157}
}
EUVIMED