D‐Alloantibody Titration Assessment Study: In Search of a Common Antibody Titration Platform—A BEST Collaborative Study
Transfusion · 2026
DOI: 10.1111/trf.70022 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Transfusion, 2026. Verfasst von Fatima A Aldarweesh und 18 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology, University of Chicago, Chicago, Illinois, USA. Hauptthemen laut MEDLINE: Isoantibodies, Rh-Hr Blood-Group System. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCATS NIH HHS, QuidelOrtho, National Institutes of Health's National Center for Advancing Translational Sciences.
Abstract (Originalsprache)
Background
Alloimmunization against D‐antigen can cause severe Hemolytic Disease of the Fetus and Newborn (HDFN). Traditionally, anti‐D‐titers are measured using a saline indirect antiglobulin test (tube testing). Anti‐D‐titers ≥8 during pregnancy trigger an escalation in maternal care. Tube testing is labor‐intensive and known for imprecision. Automated gel‐based titration is more sensitive and precise than tube titration for the detection of anti‐D. A gel titer correlated with potential fetal anemia has not been established, as studies comparing gel and tube titers provide widely variable results. This multicenter study tested anti‐D samples in parallel to characterize the difference in sensitivity between tube and automated gel assays. Study Design and Methods Patients alloimmunized to RhD had samples tested using tube and automated gel titration methods. A total of 647 samples were tested in parallel. A subset of 141 samples also had anti‐D levels quantified using continuous flow analysis (CFA). Controlled lots of R 2 R 2 red blood cells and standardized reagents were utilized.
Results
Results demonstrated that gel‐based methods yielded mean titers 2.5–3 dilutions higher than tube; this difference diminished at tube titers >128. Notably, several samples previously considered negative by tube were positive by gel. Anti‐D levels quantified by CFA demonstrated a good correlation with tube and gel testing ( R = 0.75–0.9 for tube; R = 0.85–0.89 for gel).
Discussion
A tube titer of 8 to 16 correlates with an automated gel titer of 32–128 when R 2 R 2 cells are used. Results using the CFA method correlate well with tube and gel analyses.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Pathology, University of Chicago, Chicago, Illinois, USA.
- Vitalant, Scottsdale, Arizona, USA.
- Cedars Sinai, Los Angeles, California, USA.
- Department of Pathology, Microbiology and Immunology, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
- Department of Laboratory Medicine and Pathology, University of Minnesota, Minneapolis, Minnesota, USA.
- Irish Blood Transfusion Service, Dublin, Ireland.
ORCID-Profile: Fatima A Aldarweesh, Claudia S Cohn
Förderung
- NCATS NIH HHS
- QuidelOrtho
- National Institutes of Health's National Center for Advancing Translational Sciences
Zitieren
APA
Aldarweesh, F. A., Abdallah, R., Alvarez, I. P., Andrews, J., Chlebeck, T. M., Clower, J., Costelloe, A., Figueroa, D., George, C., Evans, M., Ilstrup, S., Klapper, E. B., Mueller, A., Peterson, H., Rees, T., Seo, J., Takang, A. N., Cohn, C. S., & Biomedical Excellence for Safer Transfusion (BEST) Collaborative (2026). D‐Alloantibody Titration Assessment Study: In Search of a Common Antibody Titration Platform—A BEST Collaborative Study. Transfusion. https://doi.org/10.1111/trf.70022
Vancouver
Aldarweesh FA, Abdallah R, Alvarez IP, Andrews J, Chlebeck TM, Clower J, et al. D‐Alloantibody Titration Assessment Study: In Search of a Common Antibody Titration Platform—A BEST Collaborative Study. Transfusion. 2026. doi:10.1111/trf.70022
BibTeX
@article{Aldarweesh2026,
author = {Aldarweesh, Fatima A and Abdallah, Rim and Alvarez, Ingrid Perez and Andrews, Jennifer and Chlebeck, Therese M and Clower, Jessica and Costelloe, Aisling and Figueroa, Dolores and George, Chloe and Evans, Michael and Ilstrup, Sarah and Klapper, Ellen B and Mueller, Angela and Peterson, Hannah and Rees, Terry and Seo, Jina and Takang, Arrey N and Cohn, Claudia S and Biomedical Excellence for Safer Transfusion (BEST) Collaborative, Biomedical Excellence for Safer Transfusion (BEST) Collaborative},
title = {D‐Alloantibody Titration Assessment Study: In Search of a Common Antibody Titration Platform—A BEST Collaborative Study},
journal = {Transfusion},
year = {2026},
doi = {10.1111/trf.70022}
}
EUVIMED