EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY-NC 4.0

Incorrect blood typing and mis‐transfusion due to low‐titer group O whole blood resuscitation

Miriam Brown iD, Deva Sharma, Kaycie Atchison, Bradley M Dennis iD, Erika Hall, Angela Mueller, Christine Schaeffer, Jessica E Schucht, Jill R Streams, Toufik Tahiri, Garrett S Booth iD, Jeremy W Jacobs iD

Transfusion · 2025

DOI: 10.1111/trf.18268 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Transfusion, 2025. Verfasst von Miriam Brown und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology, Microbiology, and Immunology, Vanderbilt University Medical Center, Nashville, Tennessee, USA. Hauptthemen laut MEDLINE: ABO Blood-Group System, Blood Group Incompatibility, Blood Grouping and Crossmatching, Blood Transfusion. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Resuscitation strategies for massive hemorrhage increasingly involve the use of low‐titer group O whole blood (LTOWB) due to evidence suggesting improved patient outcomes. However, the potential risk of incorrect ABO typing following LTOWB administration, possibly leading to mis‐transfusion, remains insufficiently explored. This case series aims to highlight the potential risk of ABO mistyping associated with LTOWB transfusions in trauma settings. Study Design and Methods We retrospectively reviewed three cases involving trauma patients who received LTOWB transfusions at a high‐volume urban Level 1 Trauma Center. ABO and RhD typing were performed using automated column agglutination technology (Ortho ID‐MTS™), and discordant typing results prompted further investigations to confirm patients' true ABO type and identify mis‐transfusions.

Results

All three patients initially received LTOWB due to traumatic hemorrhage. Initial ABO typing after LTOWB administration incorrectly identified the patients as group O. Follow‐up investigations later confirmed their true blood types as group A. Two cases resulted in subsequent inadvertent transfusions of ABO‐incompatible plasma. Although no severe adverse clinical outcomes occurred, these events were reported to regulatory bodies as biologic product deviations.

Discussion

Our findings highlight a rare but clinically significant risk of ABO typing errors following LTOWB transfusion, primarily due to contamination of patient samples with donor blood. Such errors carry the potential for acute hemolytic reactions, underscoring the critical need for strict adherence to sampling protocols. Whenever possible, ABO typing should be performed prior to LTOWB administration, and samples should be drawn from a site contralateral to the transfusion.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ABO Blood-Group SystemBlood Group IncompatibilityBlood Grouping and CrossmatchingBlood TransfusionHemorrhageResuscitationHumansRetrospective StudiesTransfusion Reaction

Stichwörter der Autor:innen

RBC transfusionblood typeimmunohematology (RBC serology, blood groups)transfusion complications—noninfectioustraumawhole blood

Substanzen

ABO Blood-Group System

Autor:innen und Institutionen

  • Department of Pathology, Microbiology, and Immunology, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Quality, Safety, & Risk Prevention, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Division of Acute Care Surgery, Department of Surgery, Section of Surgical Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Division of Emergency Medicine, Vanderbilt University Medical Center, Nashville, Tennessee, USA.

ORCID-Profile: Miriam Brown, Bradley M Dennis, Garrett S Booth, Jeremy W Jacobs

Zitieren

APA

Brown, M., Sharma, D., Atchison, K., Dennis, B. M., Hall, E., Mueller, A., Schaeffer, C., Schucht, J. E., Streams, J. R., Tahiri, T., Booth, G. S., & Jacobs, J. W. (2025). Incorrect blood typing and mis‐transfusion due to low‐titer group O whole blood resuscitation. Transfusion. https://doi.org/10.1111/trf.18268

Vancouver

Brown M, Sharma D, Atchison K, Dennis BM, Hall E, Mueller A, et al. Incorrect blood typing and mis‐transfusion due to low‐titer group O whole blood resuscitation. Transfusion. 2025. doi:10.1111/trf.18268