EUVIMEDEUVIMED entdecken
Crossref

Temporal dynamics of in vitro hemostatic function in platelets cryopreserved using a novel approach for rapid issuance

Patrick S L Kwan iD, Susy Kirwan iD, Alice Tuinukuafe, Sarah Morley iD

Transfusion · 2024

DOI: 10.1111/trf.17871 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Transfusion, 2024. Verfasst von Patrick S L Kwan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Development, New Zealand Blood Service, Auckland, New Zealand. Hauptthemen laut MEDLINE: Cryopreservation, Blood Platelets, Blood Preservation, Hemostasis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 37 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Current procedures for thawing and issuing of cryopreserved platelets (CPPs) are laborious and have remained challenging in emergency settings such as blood banks and military operations. In this prospective study, a novel processing method designed to facilitate the rapid issuance of CPPs with no postthaw handling required was developed and functionally characterized in parallel with standard CPPs manufactured. Study Design and Methods Double‐dose plateletpheresis units ( n = 42) were cryopreserved at −80°C in 5%–6% dimethyl sulfoxide to produce matched pairs thawed successively over a 27‐month period for comparison between two processing arms. In contrast to the standard CPPs manufactured as standalone units, platelets were frozen in tandem with resuspending plasma in a distinct partition as a single unit in the novel method, herein referred to as tandem CPPs. Postthaw (PT) CPPs from both arms were assessed at PT0‐, 12‐, and 24‐h to measure platelet recovery, R‐time (time to clot initiation; min), and maximum amplitude (MA; clot strength; mm) using thromboelastography.

Results

In the overall dataset, mean platelet recovery was higher ( p < .0005) for tandem CPPs (83.9%) compared with standard CPPs (73.3%) at PT0; mean R‐times were faster ( p < .0005) for tandem CPPs (2.5–3.6 min) compared with standard CPPs (3.0–3.8 min); mean MA was higher for tandem CPPs (57.8–59.5 mm) compared with standard CPPs (52.1–55.8 mm) at each postthaw time point ( p < .05).

Conclusion

Robust temporal dynamics of superior hemostatic functionality were established for tandem CPPs over extended cryopreservation up to 27 months and 24 h of postthaw storage.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CryopreservationBlood PlateletsBlood PreservationHemostasisHumansProspective StudiesThrombelastographyPlateletpheresisTime FactorsMaleFemaleAdult

Stichwörter der Autor:innen

clot strengthclotting timecryopreserved plateletshemostatic potentialplatelet recoverytandem CPPthromboelastography

Autor:innen und Institutionen

  • Clinical Development, New Zealand Blood Service, Auckland, New Zealand.
  • Cellular and Tissue Laboratory, New Zealand Blood Service, Auckland, New Zealand.

ORCID-Profile: Patrick S L Kwan, Susy Kirwan, Sarah Morley

Zitieren

APA

Kwan, P. S. L., Kirwan, S., Tuinukuafe, A., & Morley, S. (2024). Temporal dynamics of in vitro hemostatic function in platelets cryopreserved using a novel approach for rapid issuance. Transfusion. https://doi.org/10.1111/trf.17871

Vancouver

Kwan PSL, Kirwan S, Tuinukuafe A, Morley S. Temporal dynamics of in vitro hemostatic function in platelets cryopreserved using a novel approach for rapid issuance. Transfusion. 2024. doi:10.1111/trf.17871

BibTeX
@article{Kwan2024,
  author = {Kwan, Patrick S L and Kirwan, Susy and Tuinukuafe, Alice and Morley, Sarah},
  title = {Temporal dynamics of in vitro hemostatic function in platelets cryopreserved using a novel approach for rapid issuance},
  journal = {Transfusion},
  year = {2024},
  doi = {10.1111/trf.17871}
}
Kostenlos starten →