Comparative analysis of the quality of platelet concentrates produced by apheresis procedures, platelet rich plasma, and buffy coat
Transfusion · 2024
DOI: 10.1111/trf.17704 ↗Kurz gefasst
Fachartikel in der Zeitschrift Transfusion, 2024. Verfasst von Meng Li und 9 weiteren Autor:innen. Beteiligte Einrichtung: Blood Research Laboratory, Chengdu Blood Center, Chengdu, P.R. China. Hauptthemen laut MEDLINE: Cell-Derived Microparticles, Blood Component Removal, Platelet-Rich Plasma. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 62 Literaturangaben. Gefördert von: Scientific Research Project of Sichuan Health Committee.
Abstract (Originalsprache)
Background
Platelet concentrates (PCs) could be prepared using either whole‐blood processes or apheresis instruments. During collection, processing and storage, some biochemical and functional changes occur, which may result in quality reduction. Quality evaluation of PCs may be helpful for the precise control of platelet (PLT) inventory to reduce the risk of refractoriness and adverse effects caused by platelet transfusion. Study Design and Methods The study was aimed to evaluate the quality of PCs which were produced by five processes: apheresis (AP) procedures (using three different cell separators: Amicus, Trima Accel and MCS + instruments), platelet rich plasma (PRP), and buffy coat (BC). A total of 100 PCs (20 of each group) were assessed in respect of routine quality control, morphology, size distribution, destroyed and activated platelets, and production of platelet‐derived microparticles (PMPs).
Results
All PCs have satisfied the recommended quality of volume, platelet count, residual WBC count, residual RBC count, pH, and sterility according to the Chinese Technical Manual. There was no difference among the 5 groups in morphology and size of PLT and PMPs. Dynamic light scattering test showed that apheresis PCs showed peaks around 10–20 nm, but not whole blood‐derived PCs. PCs prepared by Amicus had the relatively high percentage of destroyed platelet, activated platelets and PMPs than other groups.
Discussion
The data suggested high heterogeneity of PMPs, destroyed and activated platelets in PCs produced by different processes, which might be helpful to manage the platelet inventory for targeted use.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Blood Research Laboratory, Chengdu Blood Center, Chengdu, P.R. China.
ORCID-Profile: Jingyun Tang, Xuemei Fu
Förderung
- Scientific Research Project of Sichuan Health Committee
Zitieren
APA
Li, M., Zhao, Y., Chen, X., Du, X., Luo, Y., Li, Y., Kang, J., Wan, L., Tang, J., & Fu, X. (2024). Comparative analysis of the quality of platelet concentrates produced by apheresis procedures, platelet rich plasma, and buffy coat. Transfusion. https://doi.org/10.1111/trf.17704
Vancouver
Li M, Zhao Y, Chen X, Du X, Luo Y, Li Y, et al. Comparative analysis of the quality of platelet concentrates produced by apheresis procedures, platelet rich plasma, and buffy coat. Transfusion. 2024. doi:10.1111/trf.17704
BibTeX
@article{Li2024,
author = {Li, Meng and Zhao, Yuwei and Chen, Xue and Du, Xinman and Luo, Yue and Li, Ying and Kang, Jianxun and Wan, Like and Tang, Jingyun and Fu, Xuemei},
title = {Comparative analysis of the quality of platelet concentrates produced by apheresis procedures, platelet rich plasma, and buffy coat},
journal = {Transfusion},
year = {2024},
doi = {10.1111/trf.17704}
}