The effect of increased collect pump rate on collection efficiency in hematopoietic progenitor cell collection by apheresis in allogeneic adult donors—A single center analysis
Transfusion · 2023-10 · 63 (10) · 1926-1936
DOI: 10.1111/trf.17533 ↗Kurz gefasst
Fachartikel in der Zeitschrift Transfusion, online erschienen am 05.09.2023. Verfasst von Anthony Miller und 13 weiteren Autor:innen. Beteiligte Einrichtung: National Marrow Donor Program (NMDP), Minneapolis, Minnesota, USA. Hauptthemen laut MEDLINE: Blood Component Removal, Hematopoietic Stem Cell Transplantation. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 14 Literaturangaben.
Abstract (Originalsprache)
Background
Optimizing CD34 recovery while minimizing harm to hematopoietic progenitor cell donors by apheresis (HPC(A) donors) is critical to the success of allogeneic hematopoietic cell transplantation. We examined the efficacy and safety of starting allogeneic HPC(A) donors at a collect pump rate (CPR) of 2 mL/min on the Spectra Optia regardless of the inlet flow rate and/or pre‐apheresis white blood cell (WBC) count (high CPR group). Study Design and Methods A single‐center retrospective study was performed on allogeneic adult donors from 10/2020 to 12/2022. From 10/2020 to 6/19/2022, all donors had CPR of ~1 mL/min (historical group). High CPR group started 6/20/2022.
Results
During the study period, 412 donors were in historical group versus 196 (32.2%) in high CPR group. Median CD34 collection efficiency (CE) was higher and more consistent in high CPR group (55.1% vs. 53% in historical group, p < .0001) and remained significant in multivariate analysis. Although product volume was higher in high CPR group, WBC, hematocrit, and platelet concentrations were significantly lower. No difference in engraftment outcomes in patients receiving products from two groups was observed. Moreover, no differences occurred in a significant peri‐procedural adverse event or percent decrease in platelets (6.87% decrease in platelets per 100 × 10 6 CD34 cells collected versus 6.66% in historical group, p = .89). Furthermore, high CPR group had ~26 min less in collection time for every 100 × 10 6 CD34 cells collected, resulting in less positive fluid balances.
Conclusions
Starting allogeneic HPC(A) donor collection at a CPR of 2 mL/min is safe and effective.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- National Marrow Donor Program (NMDP), Minneapolis, Minnesota, USA.
- Be The Match Seattle Apheresis Collection Center, Seattle, Washington, USA.
ORCID-Profile: Huy P Pham
Zitieren
APA
Miller, A., Davies, J., Young, K., Eckman, E., Lo, M. Y., Erskine, H., Knutson, L., Ondricek, S., Margolis, J. M., Auletta, J. J., Miller, J. P., Stefanski, H. E., Devine, S., & Pham, H. P. (2023). The effect of increased collect pump rate on collection efficiency in hematopoietic progenitor cell collection by apheresis in allogeneic adult donors—A single center analysis. Transfusion, 63(10), 1926-1936. https://doi.org/10.1111/trf.17533
Vancouver
Miller A, Davies J, Young K, Eckman E, Lo MY, Erskine H, et al. The effect of increased collect pump rate on collection efficiency in hematopoietic progenitor cell collection by apheresis in allogeneic adult donors—A single center analysis. Transfusion. 2023;63(10):1926-1936. doi:10.1111/trf.17533
BibTeX
@article{Miller2023,
author = {Miller, Anthony and Davies, Jeramy and Young, Kathryn and Eckman, Emily and Lo, Melissa Y and Erskine, Hannah and Knutson, Lisa and Ondricek, Sara and Margolis, Jamie M and Auletta, Jeffery J and Miller, John P and Stefanski, Heather E and Devine, Steven and Pham, Huy P},
title = {The effect of increased collect pump rate on collection efficiency in hematopoietic progenitor cell collection by apheresis in allogeneic adult donors—A single center analysis},
journal = {Transfusion},
year = {2023},
volume = {63},
number = {10},
pages = {1926--1936},
doi = {10.1111/trf.17533}
}
EUVIMED