Fallbericht in der Zeitschrift Transfusion, 2023. Verfasst von Michel Attieh und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology and Laboratory Medicine, Emory University School of Medicine, Atlanta, Georgia, USA. Hauptthemen laut MEDLINE: Blood Grouping and Crossmatching, Blood Platelets, Platelet Transfusion. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben.
Abstract (Originalsprache)
Background
Platelet‐transfusion refractory (PR) patients do not achieve expected post‐transfusion platelet counts. We investigate suspected PR patients with post‐transfusion platelet counts, indirect platelet antibody screens (ind‐PAS), Class I HLA antibody tests (HLA‐Scr), and physical platelet crossmatch (PXM) studies. Study Design and Methods The three following cases describe possible pitfalls of laboratory tests used in PR workup and management.
Results
Case #1: Antibody testing detected antibodies to only HLA‐B13, corresponding to a 4% calculated panel reactive antibodies (CPRA; 96% predicted donor compatibility). However, PXM showed the patient compatible with 11/14 (79%) donors; two of the PXM‐incompatible units were ABO‐incompatible. Case #2: PXM revealed compatibility with 1/14 screened donors; however, the patient did not respond to the product from the compatible donor. The patient did respond to HLA‐matched product. Dilution studies provided evidence of the prozone effect, which caused negative PXM despite clinically relevant antibodies. Case #3: There was a discrepancy between the ind‐PAS and HLA‐Scr. Ind‐PAS was negative for HLA antibodies, while HLA‐Scr was positive and specificity testing corresponded to 38% CPRA. Per the package insert, the sensitivity of ind‐PAS is ~85% compared to HLA‐Scr.
Discussion
These cases highlight the importance of investigating incongruent results. Cases #1 and #2 demonstrate PXM pitfalls: ABO incompatibility can result in positive PXM and false‐negative PXM can occur in the setting of the prozone effect. Case #3 reveals the importance of knowing a test's sensitivity. Centers that only perform ind‐PAS may fail to detect HLA antibodies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Pathology and Laboratory Medicine, Emory University School of Medicine, Atlanta, Georgia, USA.
- American Red Cross, Charlotte, North Carolina, USA.
ORCID-Profile: H Cliff Sullivan
Zitieren
APA
Attieh, M., Dent, E. A., Happney, L., Roback, J. D., Alter, D. N., Barrette, E., Then, C., & Sullivan, H. C. (2023). Three patients highlighting potential pitfalls in platelet refractory testing. Transfusion. https://doi.org/10.1111/trf.17280
Vancouver
Attieh M, Dent EA, Happney L, Roback JD, Alter DN, Barrette E, et al. Three patients highlighting potential pitfalls in platelet refractory testing. Transfusion. 2023. doi:10.1111/trf.17280
BibTeX
@article{Attieh2023,
author = {Attieh, Michel and Dent, Edward A and Happney, Logan and Roback, John D and Alter, David N and Barrette, Eileen and Then, Caroline and Sullivan, H Cliff},
title = {Three patients highlighting potential pitfalls in platelet refractory testing},
journal = {Transfusion},
year = {2023},
doi = {10.1111/trf.17280}
}
EUVIMED