Robust quantification of multiplexed fluorescent protein‐based biosensors in plant tissues
The Plant Journal · 2026-07 · 127 (2)
DOI: 10.1111/tpj.71034 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Plant Journal, online erschienen am 19.07.2026. Verfasst von Valentina Levak und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biotechnology and Systems Biology, National Institute of Biology, Ljubljana, Slovenia. Hauptthemen laut MEDLINE: Biosensing Techniques, Luminescent Proteins. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The Slovenian Research and Innovation Agency.
Abstract (Originalsprache)
Genetically encoded biosensors are one of the essential tools in biological research. They enable visualization of molecules of interest from the subcellular level to entire organism level in vivo and can be used to monitor the presence of small molecules, gene expression, protein activity, and protein degradation. However, multiplexing fluorescent biosensors in plants is notoriously difficult due to signal bleed‐through and strong autofluorescence from chlorophyll. In this study, we investigated the potential of multiplexing biosensors based on the selection of reporter fluorescent proteins. We characterized the emission spectra, fluorescence lifetimes, and relative brightness of diverse fluorescent proteins in plant leaves. We show that selected proteins exhibit comparable brightness, supporting their use in co‐expression experiments and reliable quantification of individual signals. To separate three overlapping signals, we applied two different linear unmixing approaches and compared them to results obtained without unmixing. We identified the channel separation unmixing approach as the most suitable for biosensors. Additionally, we show how unmixing with the selected approach can be applied to separate autofluorescence and five fluorescent proteins. We further validated this approach in virus‐infected cells by following organelle dynamics in vivo . Finally, we demonstrate the feasibility of high‐throughput segmentation and quantification with a custom MATLAB workflow for nuclei, chloroplasts, and cytoplasm signal analysis. Overall, our work demonstrates that biosensors can be multiplexed, even when their emission spectra overlap.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Biotechnology and Systems Biology, National Institute of Biology, Ljubljana, Slovenia.
- Jožef Stefan International Postgraduate School, Ljubljana, Slovenia.
ORCID-Profile: Valentina Levak, Anže Županič, Karmen Pogačar, Katja Stare, Katja Fink, Kristina Gruden, Tjaša Lukan
Förderung
- The Slovenian Research and Innovation Agency
Zitieren
APA
Levak, V., Županič, A., Pogačar, K., Marondini, N., Stare, K., Arnšek, T., Fink, K., Gruden, K., & Lukan, T. (2026). Robust quantification of multiplexed fluorescent protein‐based biosensors in plant tissues. The Plant Journal, 127(2). https://doi.org/10.1111/tpj.71034
Vancouver
Levak V, Županič A, Pogačar K, Marondini N, Stare K, Arnšek T, et al. Robust quantification of multiplexed fluorescent protein‐based biosensors in plant tissues. The Plant Journal. 2026;127(2). doi:10.1111/tpj.71034
BibTeX
@article{Levak2026,
author = {Levak, Valentina and Županič, Anže and Pogačar, Karmen and Marondini, Nastja and Stare, Katja and Arnšek, Tina and Fink, Katja and Gruden, Kristina and Lukan, Tjaša},
title = {Robust quantification of multiplexed fluorescent protein‐based biosensors in plant tissues},
journal = {The Plant Journal},
year = {2026},
volume = {127},
number = {2},
doi = {10.1111/tpj.71034}
}
EUVIMED