EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyseOpen Access · CC BY 4.0

Systematic literature review and meta‐analysis of concordance and accuracy of pretransfusion immunohematology routine tests

Christopher Elliott, Stephanie Kelham, Liu Zhang, Stacy Grieve, Tommy Lan, Hoora Moradian, Cristina Coll-Ortega, David Gómez-Ulloa

Transfusion Medicine · 2025

DOI: 10.1111/tme.70010 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Transfusion Medicine, 2025. Verfasst von Christopher Elliott und 7 weiteren Autor:innen. Beteiligte Einrichtung: NHS Blood and Transplant, Newcastle Blood Centre, Bristol, UK. Hauptthemen laut MEDLINE: Blood Grouping and Crossmatching, Blood Transfusion, ABO Blood-Group System, Isoantibodies. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Grifols.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This study aimed to assess the concordance and comparative accuracy of commercially available immunohematology (IH) tests for pretransfusion testing.

Background

Pretransfusion tests are intended to ensure donor blood is matched with a compatible recipient. Automated testing has become the mainstay since the commercialisation of IH analysers, because of their reduced risk of human error and increased efficiency. Methods/Materials A systematic literature review (SLR) was performed to identify studies evaluating the concordance and sensitivity/specificity of IH tests for ABO/RhD typing, antibody screening, or antibody identification. Pairwise meta‐analysis of concordance and sensitivity/specificity of IH tests was conducted when feasible.

Results

The SLR identified 48 publications, of which 30 were included for meta‐analysis. ID/IH gel (Bio‐Rad), DG gel (Grifols), MTS/BioVue gel (Ortho Clinical Diagnostics), and Capture R (Immucor/Werfen) all had almost 100% pooled concordance with each other in ABO/RhD typing and antibody screening. Antibody identification results varied across studies, and pooled concordance rates were lower: 97.53% for DG gel versus ID/IH gel, 85.26% for ID/IH gel vs. MTS/BioVue gel, 85.54% for DG gel versus MTS/BioVue gel, and 71.19% for Capture R versus MTS/BioVue gel. For antibody screening, ID/IH gel, DG gel, and MTS/BioVue gel had pooled sensitivities of 94.23%, 96.31%, and 97.27%, respectively, with a pooled specificity of ~100% for all three tests.

Conclusion

All tests had good concordance in ABO/RhD typing and antibody screening, and lower pooled concordance rates for antibody identification. For antibody screening, 95% pooled sensitivity and ~100% specificity were estimated for DG gel, MTS/BioVue gel, and ID/IH gel.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood Grouping and CrossmatchingBlood TransfusionABO Blood-Group SystemIsoantibodiesRh-Hr Blood-Group SystemHumans

Stichwörter der Autor:innen

accuracyantibody identificationantibody screeningblood typingconcordanceimmunohematologymeta‐analysispretransfusion testingsensitivityspecificity

Substanzen

ABO Blood-Group SystemIsoantibodiesRh-Hr Blood-Group System

Autor:innen und Institutionen

  • NHS Blood and Transplant, Newcastle Blood Centre, Bristol, UK.
  • Scientific Services, LifeShare Blood Center, Shreveport, Louisiana, USA.
  • Cytel, Inc., Cambridge, MA, USA.
  • Global HEOR & RWE, Grifols SA, Sant Cugat Del Vallès, Spain.

Förderung

  • Grifols

Zitieren

APA

Elliott, C., Kelham, S., Zhang, L., Grieve, S., Lan, T., Moradian, H., Coll-Ortega, C., & Gómez-Ulloa, D. (2025). Systematic literature review and meta‐analysis of concordance and accuracy of pretransfusion immunohematology routine tests. Transfusion Medicine. https://doi.org/10.1111/tme.70010

Vancouver

Elliott C, Kelham S, Zhang L, Grieve S, Lan T, Moradian H, et al. Systematic literature review and meta‐analysis of concordance and accuracy of pretransfusion immunohematology routine tests. Transfusion Medicine. 2025. doi:10.1111/tme.70010

BibTeX
@article{Elliott2025,
  author = {Elliott, Christopher and Kelham, Stephanie and Zhang, Liu and Grieve, Stacy and Lan, Tommy and Moradian, Hoora and Coll-Ortega, Cristina and Gómez-Ulloa, David},
  title = {Systematic literature review and meta‐analysis of concordance and accuracy of pretransfusion immunohematology routine tests},
  journal = {Transfusion Medicine},
  year = {2025},
  doi = {10.1111/tme.70010}
}
Kostenlos starten →