EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The impact of pressure and temperature on the quality of suspended red blood cells: An ex vivo simulation study

Chunyu Feng iD, Rui Fan, Haimei Ma, Huan Zhang iD

Transfusion Medicine · 2025

DOI: 10.1111/tme.13141 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Transfusion Medicine, 2025. Verfasst von Chunyu Feng und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Clinical Medicine, Tsinghua University, Beijing, China. Hauptthemen laut MEDLINE: Erythrocytes, Blood Preservation, Erythrocyte Transfusion. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Tsinghua Precision Medicine Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This study aims to explore the impact of pressurisation and simultaneous warming at a combination of 50 kPa and 46°C on the quality of suspended red blood cells in an ex vivo environment.

Background

During massive rapid blood transfusion, pressure and temperature‐controlled blood warming devices are often used to prevent hypothermia caused by the infusion of large amounts of cold blood. If the pressure and temperature are not properly applied during this process, it can endanger the patient's life safety. Methods/Materials 400 mL of human suspended red blood cells stored at 2–6°C were subjected to pressure and simultaneous warming at a combination of 50 kPa and 46°C. Changes in blood temperature and blood quality‐related indicators before and after warming under pressure were detected, with the procedure repeated six times.

Results

In the ex vivo simulated test environment, there were no statistically significant differences in routine blood indicators, biochemical indicators, and hemolysis rates of suspended red blood cells before and after pressure and warming transfusion at 50 kPa pressure and 46°C temperature (P>0.05). There were no significant changes in osmotic fragility after pressure and warming transfusion, and no obvious hemolysis was observed in the morphology of suspended red blood cells under an electron microscope.

Conclusion

In the ex vivo simulated test environment, pressure and warming transfusion at 50 kPa pressure and 46°C temperature had no significant impact on blood quality, and the blood quality met the standards for the use of blood products.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ErythrocytesBlood PreservationErythrocyte TransfusionHumansPressureHemolysisTemperatureMale

Stichwörter der Autor:innen

blood transfusionfluid warminghaemolysisheating

Autor:innen und Institutionen

  • School of Clinical Medicine, Tsinghua University, Beijing, China.
  • Department of Anesthesiology, Beijing Tsinghua Changgung Hospital, Beijing, China.
  • Department of Blood Transfusion, Beijing Tsinghua Changgung Hospital, Beijing, China.

ORCID-Profile: Chunyu Feng, Huan Zhang

Förderung

  • Tsinghua Precision Medicine Foundation

Zitieren

APA

Feng, C., Fan, R., Ma, H., & Zhang, H. (2025). The impact of pressure and temperature on the quality of suspended red blood cells: An ex vivo simulation study. Transfusion Medicine. https://doi.org/10.1111/tme.13141

Vancouver

Feng C, Fan R, Ma H, Zhang H. The impact of pressure and temperature on the quality of suspended red blood cells: An ex vivo simulation study. Transfusion Medicine. 2025. doi:10.1111/tme.13141

BibTeX
@article{Feng2025,
  author = {Feng, Chunyu and Fan, Rui and Ma, Haimei and Zhang, Huan},
  title = {The impact of pressure and temperature on the quality of suspended red blood cells: An ex vivo simulation study},
  journal = {Transfusion Medicine},
  year = {2025},
  doi = {10.1111/tme.13141}
}
Kostenlos starten →