Establishment and discussion of autoverification rules for transfusion compatibility testing

Daobo Peng iD, Xiaohui Wang iD, Jie Huang iD

Transfusion Medicine · 2024

DOI: 10.1111/tme.13077 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Transfusion Medicine, 2024. Verfasst von Daobo Peng und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Transfusion Medicine, Southern Medical University Nanfang Hospital, Guangzhou, China. Hauptthemen laut MEDLINE: Blood Grouping and Crossmatching, Blood Transfusion. Die Arbeit nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To develop an automated verification workflow for transfusion compatibility testing (TCT) based on the AUTO10‐A guidelines and blood group serology characteristics and to conduct a simulated validation of the test and subtest results by assessing the appropriateness of the autoverification rules.

Background

The accuracy of TCT results is a fundamental prerequisite for ensuring the safety of blood transfusions. However, the verification of these results still requires manual intervention. Materials and Methods Five autoverification rules and their standards were determined: agglutination intensity, normal results, logical relationships, delta checks and interlaboratory test comparisons. The established categories and standards for the five rules were retrospectively validated using 13 506 samples (requests) that had been manually verified in our laboratory from January 2020 to June 2023.

Results

A total of 66 638 test items were involved in the autoverification, with 3844 items violating the verification rules, resulting in a pass rate of 96.10%. Considering individual test items, four tests had a pass rate of more than 90% in both the test item result table and the test subitem result table. However, there were significant differences in the pass rates between different tests. The same conclusion can be drawn when the unit is requests. The different standards set for the agglutination intensity and the delta check in the ABO typing testing subitems showed significant differences in pass rates.

Discussion

The incorporation of manually verified results into the automated verification simulation indicated that the five rules established in this study have good applicability, and appropriate standards can lead to reasonable pass rates.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood Grouping and CrossmatchingBlood TransfusionHumansRetrospective StudiesBlood Group AntigensFemale

Stichwörter der Autor:innen

autoverification rulesblood transfusion safetylaboratory qualitytransfusion compatibility testing

Substanzen

Blood Group Antigens

Autor:innen und Institutionen

  • Department of Transfusion Medicine, Southern Medical University Nanfang Hospital, Guangzhou, China.
  • Department of Transfusion Medicine, Southern Medical University Nanfang Hospital Zengcheng Campus, Guangzhou, China.

ORCID-Profile: Daobo Peng, Xiaohui Wang, Jie Huang

Zitieren

APA

Peng, D., Wang, X., & Huang, J. (2024). Establishment and discussion of autoverification rules for transfusion compatibility testing. Transfusion Medicine. https://doi.org/10.1111/tme.13077

Vancouver

Peng D, Wang X, Huang J. Establishment and discussion of autoverification rules for transfusion compatibility testing. Transfusion Medicine. 2024. doi:10.1111/tme.13077

BibTeX
@article{Peng2024,
  author = {Peng, Daobo and Wang, Xiaohui and Huang, Jie},
  title = {Establishment and discussion of autoverification rules for transfusion compatibility testing},
  journal = {Transfusion Medicine},
  year = {2024},
  doi = {10.1111/tme.13077}
}
Kostenlos starten →