Limited Risk of Microbial Contamination During Hypothermic and Normothermic Machine Perfusion of Donor Kidneys
Transplant Infectious Disease · 2025
DOI: 10.1111/tid.70019 ↗Kurz gefasst
Fachartikel in der Zeitschrift Transplant Infectious Disease, 2025. Verfasst von Julia S Slagter und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Erasmus MC Transplant Institute, Division of HPB and Transplant Surgery, Erasmus Medical Center Rotterdam, Rotterdam, the Neth…. Hauptthemen laut MEDLINE: Kidney Transplantation, Perfusion, Organ Preservation, Kidney. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
Both hypothermic machine perfusion (HMP) and normothermic machine perfusion (NMP) are increasingly used for preservation of deceased donor kidneys. However, especially NMP can pose as a risk for microbial contamination of the kidney graft as the 37°C perfusate can act as a breeding ground for microbial contaminants.
Methods
In this study, we investigated the cultures of HMP and NMP perfusates of deceased donor kidneys.
Results
Between January 2021 and April 2024, a total of 99 perfusates were examined (73 HMP and 26 NMP perfusates)‐. We found that contamination of HMP perfusate was common, occurring in 21 of 73 cultures (29%). Most bacteria originated from the skin. Microbial contamination during NMP was rare, occurring only in 2 of 26 cultures (8%). Microbial contamination during machine perfusion did not lead to infectious complications in the recipients.
Conclusion
Machine perfusion poses a very limited risk of infection in kidney transplant recipients. image
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Surgery, Erasmus MC Transplant Institute, Division of HPB and Transplant Surgery, Erasmus Medical Center Rotterdam, Rotterdam, the Netherlands.
- Department of Medical Microbiology and Infectious Diseases, Erasmus Medical Center Rotterdam, Rotterdam, the Netherlands.
- Department of Internal Medicine Erasmus MC, Erasmus Medical Center Rotterdam, Rotterdam, the Netherlands.
- Department of Internal Medicine Erasmus MC Transplant Institute, Division of Nephrology and Transplantation, Erasmus Medical Center Rotterdam, Rotterdam, the Netherlands.
ORCID-Profile: Julia S Slagter, Carolina A M Schurink, Marlies E J Reinders, Robert J Porte, Robert C Minnee
Zitieren
APA
Slagter, J. S., Schurink, C. A. M., Chong, G. M., Reinders, M. E. J., Porte, R. J., & Minnee, R. C. (2025). Limited Risk of Microbial Contamination During Hypothermic and Normothermic Machine Perfusion of Donor Kidneys. Transplant Infectious Disease. https://doi.org/10.1111/tid.70019
Vancouver
Slagter JS, Schurink CAM, Chong GM, Reinders MEJ, Porte RJ, Minnee RC. Limited Risk of Microbial Contamination During Hypothermic and Normothermic Machine Perfusion of Donor Kidneys. Transplant Infectious Disease. 2025. doi:10.1111/tid.70019