Using single antigen specificity magnetic beads for the isolation of specific antibodies against HLA antigens
HLA · 2024
DOI: 10.1111/tan.15490 ↗Kurz gefasst
Fachartikel in der Zeitschrift HLA, 2024. Verfasst von Tri T M Vu und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Research and Development, One Lambda, Inc. (A Part of Thermo Fisher Scientific Inc.), West Hills, California, USA. Hauptthemen laut MEDLINE: Antibodies, HLA Antigens. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
The presence of multiple donor‐specific antibodies (DSAs) targeting HLA antigens poses a challenge to transplantation. Various techniques, including the use of recombinant cell lines and crossmatch cells have been developed to isolate DSAs. To simplify the extraction of HLA‐specific DSAs from complex sera, we introduced magnetic beads with single HLA specificity (MagSort). Sera were treated with MagSort, allowing HLA‐specific antibodies to bind to the beads, and these specific antibodies were subsequently eluted. MagSort beads, coated with 59 different HLA variants, underwent testing through 1329 adsorption/elution processes, demonstrating their effectiveness and specificity in adsorbing and eluting HLA‐specific antibodies. The MagSort method proves comparable to the cell method, showing similar isolated antibody binding patterns. The isolated antibody binding patterns from MagSort reveal both known eplets and unknown patterns, suggesting its utility for eplet discovery. Additionally, MagSort proved effective in extracting signals for flow cytometry cross‐matching, offering a means to assess the binding capability of isolated antibodies against specific donor cells.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Research and Development, One Lambda, Inc. (A Part of Thermo Fisher Scientific Inc.), West Hills, California, USA.
- Allogen Laboratories, Cleveland Clinic, Cleveland, Ohio, USA.
ORCID-Profile: Tri T M Vu, Quansheng Zhu, David Lowe, Rui Pei
Zitieren
APA
Vu, T. T. M., Zhang, A., Wang, R., Mathew, S., Abeywardana, T., Beltran-Lemus, M., Ma, V., Libby, M., Thomas, D., Wakefield, I., Zhu, Q., Lowe, D., & Pei, R. (2024). Using single antigen specificity magnetic beads for the isolation of specific antibodies against HLA antigens. HLA. https://doi.org/10.1111/tan.15490
Vancouver
Vu TTM, Zhang A, Wang R, Mathew S, Abeywardana T, Beltran-Lemus M, et al. Using single antigen specificity magnetic beads for the isolation of specific antibodies against HLA antigens. HLA. 2024. doi:10.1111/tan.15490
BibTeX
@article{Vu2024,
author = {Vu, Tri T M and Zhang, Aiwen and Wang, Ronald and Mathew, Shalu and Abeywardana, Tharindumala and Beltran-Lemus, Marissa and Ma, Vincent and Libby, Mary and Thomas, Dawn and Wakefield, Ito and Zhu, Quansheng and Lowe, David and Pei, Rui},
title = {Using single antigen specificity magnetic beads for the isolation of specific antibodies against HLA antigens},
journal = {HLA},
year = {2024},
doi = {10.1111/tan.15490}
}
EUVIMED