EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

A Framework for Evaluating the Endurance Properties of Custom‐Made Osseointegrated Prostheses for Transfemoral Amputees Combining In Silico Simulations and Mechanical Testing

Giulia Galteri, Cristina Curreli, Giacomo Dozza, Marco Viceconti, Luca Cristofolini

Strain · 2026-12 · 62 (6)

DOI: 10.1111/str.70045 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Strain, online erschienen am 16.11.2026. Verfasst von Giulia Galteri und 4 weiteren Autor:innen. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

According to the European Medical Device Regulation (MDR), new or modified implants must undergo preclinical testing to characterise their safety and performance. However, no specific standard defines how to evaluate the endurance behaviour of osseointegrated transfemoral prostheses, making the mechanical evaluation of such devices challenging. To address this limitation, the present study aimed to develop a combined experimental–numerical framework to support the endurance assessment of custom‐made osseointegrated transfemoral prostheses. The rationale for endurance testing was developed based on the loading and boundary conditions defined in the ISO 7206 standards for hip stems. A simplified stem geometry instrumented with six strain gauge rosettes was used to measure strains under controlled quasi‐static loading conditions. In parallel, a finite element (FE) model of the same experimental configuration was developed. The predictive accuracy of the FE model was assessed through direct comparison with experimentally measured strains. A sensitivity analysis was performed to evaluate the influence of uncertainties in the input parameters on FE predictions. The agreement between experimental and numerical results was excellent, with R 2 ≥ 0.998 for all gauges. The normalised root mean square error (%RMSE) was consistently below 2.7%, whereas the peak error remained below 3.9%. These findings supported the ability of the numerical methodology to reproduce the experimental loading conditions and accurately predict local strains. The numerical methodology, validated against experimental measurements using the simplified stem geometry, was subsequently applied to the OsteoCustom stem as a proof of concept. Overall, this work demonstrates the feasibility of integrating experimentally validated FE modelling into an endurance‐assessment framework for osseointegrated stems. The proposed methodology can support the identification of mechanically critical design configurations and guide subsequent experimental endurance testing of custom‐made implants.

Zitieren

APA

Galteri, G., Curreli, C., Dozza, G., Viceconti, M., & Cristofolini, L. (2026). A Framework for Evaluating the Endurance Properties of Custom‐Made Osseointegrated Prostheses for Transfemoral Amputees Combining In Silico Simulations and Mechanical Testing. Strain, 62(6). https://doi.org/10.1111/str.70045

Vancouver

Galteri G, Curreli C, Dozza G, Viceconti M, Cristofolini L. A Framework for Evaluating the Endurance Properties of Custom‐Made Osseointegrated Prostheses for Transfemoral Amputees Combining In Silico Simulations and Mechanical Testing. Strain. 2026;62(6). doi:10.1111/str.70045

BibTeX
@article{Galteri2026,
  author = {Galteri, Giulia and Curreli, Cristina and Dozza, Giacomo and Viceconti, Marco and Cristofolini, Luca},
  title = {A Framework for Evaluating the Endurance Properties of Custom‐Made Osseointegrated Prostheses for Transfemoral Amputees Combining In Silico Simulations and Mechanical Testing},
  journal = {Strain},
  year = {2026},
  volume = {62},
  number = {6},
  doi = {10.1111/str.70045}
}
Kostenlos starten →