EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Treatment of Cherry Angiomas With a 1064‐nm Long‐Pulse Laser: A Multi‐Time‐Point, Multi‐Dimensional Quantitative Assessment Based on Antera 3D

Yuanjia Tu, Changhan Chen, Yuzhen Huang, Xiaxia Chen, Youhui Ke, Youhui Ke

Skin Research and Technology · 2026-11 · 32 (11)

DOI: 10.1111/srt.70407 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Skin Research and Technology, online erschienen am 18.11.2026. Verfasst von Yuanjia Tu und 5 weiteren Autor:innen. Die Arbeit nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Objective Cherry angioma (CA) is a common benign cutaneous vascular proliferative lesion that predominantly affects middle‐aged and elderly individuals. The long‐pulsed 1064 nm Nd:YAG laser (LP‐Nd:YAG laser) is an effective treatment for CA; however, previous studies have lacked quantitative descriptions of the immediate post‐treatment response and its correlation with clinical efficacy. This study aims to quantitatively evaluate the immediate response to LP‐Nd:YAG laser treatment for CA and investigate its association with final clinical outcomes.

Methods

A total of 129 CAs in 20 patients treated between December 2024 and January 2025 were enrolled. The red color ratio (RCR) was used to quantify the degree of redness, and the improvement rate reflected the pre‐to post‐treatment changes. Clinical photographs were taken using a digital camera, and three‐dimensional multispectral images were acquired using the Antera 3D system at three time points: baseline (T0), immediately post‐treatment (T1), and 2 months post‐treatment (T2), to assess mean hemoglobin concentration (HbI), redness score, RCR, and lesion volume. Two physicians specializing in aesthetic medicine blindly evaluated clinical efficacy using a binary scoring system. The correlation between the percentage decrease in HbI at T1 (ΔHbI%) and the clinical score at T2 was analysed. A receiver operating characteristic (ROC) curve was used to determine the optimal ΔHbI% cutoff for predicting “complete clearance” at 2 months.The primary analysis was performed on a per‐patient basis, with lesion‐level analysis as a sensitivity analysis.

Results

HbI decreased significantly from 28.24 ± 7.05 at baseline to 13.76 ± 3.26 immediately post‐treatment ( p < 0.001), and further to 5.83 ± 4.52 at 2 months ( p < 0.001). There was no significant difference in intrinsic laser responsiveness between elevated and flat CAs; after adjusting for baseline HbI, the difference in ΔHbI% between the two groups was not statistically significant ( F = 0.057, p = 0.812). ΔHbI% was significantly associated with complete clearance at 2 months (GEE: OR = 1.23, 95% CI: 1.10–1.39, p < 0.001). In the per‐patient ROC analysis, the AUC of ΔHbI% for predicting complete clearance at 2 months was 0.802 (95% CI: 0.588–1.000), with an optimal cutoff value of 50.1%, sensitivity of 66.7%, and specificity of 87.5%. In the lesion‐level sensitivity analysis, the AUC was 0.93 (95% CI: 0.72–1.00), with an optimal cutoff value of 39.0%, sensitivity of 92.4%, and specificity of 90.9%.

Conclusion

Based on clinical observations and Antera 3D imaging assessments, LP‐Nd:YAG laser treatment for CA demonstrates good overall efficacy and a favorable safety profile. Antera 3D can sensitively capture the immediate physiological response to laser therapy, and the degree of immediate blood flow reduction may serve as an early predictor of the final clinical outcome. Clinical Trial Registration Information: ChiCTR2400092847

Zitieren

APA

Tu, Y., Chen, C., Huang, Y., Chen, X., Ke, Y., & Ke, Y. (2026). Treatment of Cherry Angiomas With a 1064‐nm Long‐Pulse Laser: A Multi‐Time‐Point, Multi‐Dimensional Quantitative Assessment Based on Antera 3D. Skin Research and Technology, 32(11). https://doi.org/10.1111/srt.70407

Vancouver

Tu Y, Chen C, Huang Y, Chen X, Ke Y, Ke Y. Treatment of Cherry Angiomas With a 1064‐nm Long‐Pulse Laser: A Multi‐Time‐Point, Multi‐Dimensional Quantitative Assessment Based on Antera 3D. Skin Research and Technology. 2026;32(11). doi:10.1111/srt.70407

BibTeX
@article{Tu2026,
  author = {Tu, Yuanjia and Chen, Changhan and Huang, Yuzhen and Chen, Xiaxia and Ke, Youhui and Ke, Youhui},
  title = {Treatment of Cherry Angiomas With a 1064‐nm Long‐Pulse Laser: A Multi‐Time‐Point, Multi‐Dimensional Quantitative Assessment Based on Antera 3D},
  journal = {Skin Research and Technology},
  year = {2026},
  volume = {32},
  number = {11},
  doi = {10.1111/srt.70407}
}
Kostenlos starten →