A morphological analysis of calcium hydroxylapatite and poly‐ l ‐lactic acid biostimulator particles
Skin Research and Technology · 2024-06 · 30 (6)
DOI: 10.1111/srt.13764 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Skin Research and Technology, online erschienen am 09.06.2024. Verfasst von Alec D McCarthy und 5 weiteren Autor:innen. Beteiligte Einrichtung: Medical Affairs, Merz Aesthetics, Raleigh, North Carolina, USA. Hauptthemen laut MEDLINE: Durapatite, Polyesters, Dermal Fillers. Die Arbeit wurde bisher 47-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Merz Aesthetics.
Abstract (Originalsprache)
Injectable fillers, pivotal in aesthetic medicine, have evolved significantly with recent trends favoring biostimulators like calcium hydroxylapatite (CaHA‐CMC; Radiesse, Merz Aesthetics, Raleigh, NC) and poly‐ l ‐lactic acid (PLLA; Sculptra Aesthetics, Galderma, Dallas, TX). This study aims to compare the particle morphology of these two injectables and examine its potential clinical implications. Utilizing advanced light and scanning electron microscopy techniques, the physical characteristics of CaHA‐CMC and PLLA particles were analyzed, including shape, size, circularity, roundness, aspect ratio, and quantity of phagocytosable particles. The findings reveal several morphological contrasts: CaHA‐CMC particles exhibited a smooth, homogenous, spherical morphology with diameters predominantly ranging between 20 and 45 µm, while PLLA particles varied considerably in shape and size, appearing as micro flakes ranging from 2 to 150 µm in major axis length. The circularity and roundness of CaHA‐CMC particles were significantly higher compared to PLLA, indicating a more uniform shape. Aspect ratio analysis further underscored these differences, with CaHA‐CMC particles showing a closer resemblance to circles, unlike the more oblong PLLA particles. Quantification of the phagocytosable content of both injectables revealed a higher percentage of phagocytosable particles in PLLA. These morphological distinctions may influence the tissue response to each treatment. CaHA‐CMC's uniform, spherical particles may result in reduced inflammatory cell recruitment, whereas PLLA's heterogeneous particle morphology may evoke a more pronounced inflammatory response.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Medical Affairs, Merz Aesthetics, Raleigh, North Carolina, USA.
- R&D, Merz Aesthetics GmbH, Frankfurt, Germany.
- Ocean Drive Plastic Surgery, Vero Beach, Florida, USA.
- University of Nebraska Medical Center, Omaha, Nebraska, USA.
- SOM Aesthetics, Encinitas, California, USA.
ORCID-Profile: Christian Hartmann
Förderung
- Merz Aesthetics
Zitieren
APA
McCarthy, A. D., Hartmann, C., Durkin, A., Shahriar, S., Khalifian, S., & Xie, J. (2024). A morphological analysis of calcium hydroxylapatite and poly‐ l ‐lactic acid biostimulator particles. Skin Research and Technology, 30(6). https://doi.org/10.1111/srt.13764
Vancouver
McCarthy AD, Hartmann C, Durkin A, Shahriar S, Khalifian S, Xie J. A morphological analysis of calcium hydroxylapatite and poly‐ l ‐lactic acid biostimulator particles. Skin Research and Technology. 2024;30(6). doi:10.1111/srt.13764
BibTeX
@article{McCarthy2024,
author = {McCarthy, Alec D and Hartmann, Christian and Durkin, Alan and Shahriar, Shatil and Khalifian, Saami and Xie, Jingwei},
title = {A morphological analysis of calcium hydroxylapatite and poly‐ l ‐lactic acid biostimulator particles},
journal = {Skin Research and Technology},
year = {2024},
volume = {30},
number = {6},
doi = {10.1111/srt.13764}
}
EUVIMED