EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Heating of metallic orthodontic devices during anti‐aging treatment with vacuum and electromagnetic fields: In vitro study

Antonio Scarano iD, Domenico Amuso, Roberto Amore, Sergio Alexandre Gehrke, Sergio Rexhep Tari

Skin Research and Technology · 2024

DOI: 10.1111/srt.13687 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Skin Research and Technology, 2024. Verfasst von Antonio Scarano und 4 weiteren Autor:innen. Beteiligte Einrichtung: Dean of Master course in Aesthetic Medicine, Department of Innovative Technologies in Medicine and Dentistry, University of Chieti-Pescara, Chieti, I…. Hauptthemen laut MEDLINE: Titanium, Electromagnetic Fields, Nickel. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The physical appearance of an individual plays a primary role as it influences the opinion of the viewer. For this reason, orthodontic therapy to improve perceived aesthetics is in high demand among patients. This factor, combined with the increase in the number of non‐invasive facial aesthetic treatments, has led to the need to understand potential risk factors in the application of medical devices to the perioral skin in patients with fixed orthodontic appliances. The aim of this study was to evaluate in vitro heating of the orthodontic bracket following electromagnetic fields and negative pressure (V‐EMF) used as an anti‐aging treatment.

Methods

Two different types of titanium alloy wires, one made of “beta‐Titanium” alloy and the other “Ni‐Ti” (DW Lingual Systems GmbH—Bad Essen—Germany) were used. The orthodontic wires and brackets mounted on a resin mouth were covered with porcine muscle tissue, then subjected to anti‐aging therapy with a Bi‐one LifeTouchTherapy medical device (Expo Italia Srl—Florence—Italy) which generates a combination of vacuum and electromagnetic fields (V‐EMF) already adopted for antiaging therapy. During administration of the therapy, the orthodontic brackets and porcine tissue were thermally monitored using a Wavetek Materman TMD90 thermal probe (Willtek Communications GmbH—Germany). In total 20 orthodontic mouths were used, 10 with Beta Titanium wires and 10 with Nickel Titanium wires.

Results

A temperature increase of about 1°C was recorded in each group. The outcome of the present research shows that the absolute temperatures measured on orthodontic appliances, which, despite having a slightly different curve, both show an increase in temperature of 1.1°C at the end of the session, thus falling well within the safety range of 2°C as specified by the standard CENELEC EN 45502‐1. Therefore, V‐EMF therapy can be considered safe for the entire dental system and for metal prostheses, which tend to heat up at most as much as biological tissue (+0.9°C/1.1°C vs. 1.1°C/1.1°C).

Conclusion

In conclusion, anti‐aging therapy with V‐EMF causes a thermal increase on orthodontic brackets that is not harmful to pulp health.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TitaniumElectromagnetic FieldsNickelHumansAnimalsSwineVacuumOrthodontic WiresAlloysMaterials TestingHot Temperature

Stichwörter der Autor:innen

anti‐aging treatmentelectromagnetic fieldsheating bracketorthodontic devicesvacuum

Substanzen

titanium nickelidebeta titaniumTitaniumAlloysNickel

Autor:innen und Institutionen

  • Dean of Master course in Aesthetic Medicine, Department of Innovative Technologies in Medicine and Dentistry, University of Chieti-Pescara, Chieti, Italy.
  • Department of Research, Bioface/PgO/UCAM, Montevideo, Uruguay. Department of Biotechnology, Universidad Católica de Murcia (UCAM), Murcia, Spain.

ORCID-Profile: Antonio Scarano

Zitieren

APA

Scarano, A., Amuso, D., Amore, R., Gehrke, S. A., & Tari, S. R. (2024). Heating of metallic orthodontic devices during anti‐aging treatment with vacuum and electromagnetic fields: In vitro study. Skin Research and Technology. https://doi.org/10.1111/srt.13687

Vancouver

Scarano A, Amuso D, Amore R, Gehrke SA, Tari SR. Heating of metallic orthodontic devices during anti‐aging treatment with vacuum and electromagnetic fields: In vitro study. Skin Research and Technology. 2024. doi:10.1111/srt.13687

BibTeX
@article{Scarano2024,
  author = {Scarano, Antonio and Amuso, Domenico and Amore, Roberto and Gehrke, Sergio Alexandre and Tari, Sergio Rexhep},
  title = {Heating of metallic orthodontic devices during anti‐aging treatment with vacuum and electromagnetic fields: In vitro study},
  journal = {Skin Research and Technology},
  year = {2024},
  doi = {10.1111/srt.13687}
}
Kostenlos starten →