Multispectral near‐infrared spectroscopy study evaluating the effect of razor design on shaving‐induced erythema
Skin Research and Technology · 2024
DOI: 10.1111/srt.13598 ↗Kurz gefasst
Fachartikel in der Zeitschrift Skin Research and Technology, 2024. Verfasst von Chris Boodoo und 6 weiteren Autor:innen. Beteiligte Einrichtung: MIMOSA Diagnostics, Toronto, Ontario, Canada. Hauptthemen laut MEDLINE: Hair Removal. Die Arbeit nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hensons Shaving Inc.
Abstract (Originalsprache)
Background
While shaving‐induced erythema is a common inflammatory skin issue, there is a lack of quantitative information on how well a shaving product performs in this regard. In this study, multispectral near‐infrared spectroscopy (NIRS) imaging was used to quantitatively and qualitatively measure the extent of shaving‐induced erythema. The research compares a safety razor and a cartridge razor to evaluate their impact on skin irritation. Materials and methods Fifty‐nine healthy male volunteers without pre‐existing skin conditions were enrolled. Basic demographics were recorded, and participants' faces or necks were imaged before shaving. Shaving was conducted on the right side of the face/neck with the safety razor and on the left side of the face/neck using the 3‐blade cartridge razor. Images were captured immediately after shaving, at 5 and 10 min post‐shaving.
Results
Tissue oxygen saturation (StO2) measurements demonstrated that the safety razor induced significantly less erythema than the cartridge razor. Immediately after shaving, 40.3% of skin shaved with the safety razor had erythema compared to 57.6% for the cartridge razor. At 5 min post‐shaving, 36.5% of skin shaved with the safety razor had erythema, compared to 53.8% of cartridge razor.
Conclusions
Multispectral NIRS revealed significant differences in shaving‐induced erythema between safety and cartridge razors. Safety razors demonstrated a lower incidence of erythema, suggesting a potential advantage for individuals prone to skin irritation. This study contributes valuable insights into skin irritation and highlights the potential of multispectral NIRS in dermatology research.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- MIMOSA Diagnostics, Toronto, Ontario, Canada.
- Department of Surgery, Dalhousie Universitys, Halifax, Nova Scotia, Canada.
- Innovators in Residence Program, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada.
ORCID-Profile: Anna Khimchenko
Förderung
- Hensons Shaving Inc
Zitieren
APA
Boodoo, C., Duta, D., Swift, N., Hunter, P., Khimchenko, A., Leung, G., & Cross, K. (2024). Multispectral near‐infrared spectroscopy study evaluating the effect of razor design on shaving‐induced erythema. Skin Research and Technology. https://doi.org/10.1111/srt.13598
Vancouver
Boodoo C, Duta D, Swift N, Hunter P, Khimchenko A, Leung G, et al. Multispectral near‐infrared spectroscopy study evaluating the effect of razor design on shaving‐induced erythema. Skin Research and Technology. 2024. doi:10.1111/srt.13598
BibTeX
@article{Boodoo2024,
author = {Boodoo, Chris and Duta, Dragos and Swift, Nathan and Hunter, Paul and Khimchenko, Anna and Leung, General and Cross, Karen},
title = {Multispectral near‐infrared spectroscopy study evaluating the effect of razor design on shaving‐induced erythema},
journal = {Skin Research and Technology},
year = {2024},
doi = {10.1111/srt.13598}
}
EUVIMED