Beobachtungsstudie in der Zeitschrift Seminars in Dialysis, 2026. Verfasst von Gurkan Yurteri und 1 weiteren Autor:innen. Beteiligte Einrichtung: Hemodialysis Unit, Rentek Dialysis Center, Istanbul, Turkey. Hauptthemen laut MEDLINE: Membranes, Artificial, Renal Dialysis, Kidney Failure, Chronic. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Due to the accumulation of uremic toxins, hemodialysis patients exhibit a variety of symptoms and increased mortality. With their unique pore size and distribution, medium cut‐off (MCO) membranes can provide clearance of middle‐sized uremic toxins without causing albumin loss. Such a property may decrease overall mortality in hemodialysis patients. This study aims to analyze the effects of MCO membranes on the clearance of β 2 ‐microglobulin, tumor necrosis factor α (TNF‐α), and interleukin 6 (IL‐6) to assess the safety of using these membranes and to compare two different MCO membranes.

Methods

This was a prospective observational study. Sixty hemodialysis patients who had been dialyzed thrice weekly via high flux dialyzers were switched to one of two MCO dialyzers (Elisio Hx or Theranova) for 1 month. The mean age was 58.7 ± 13.4 years, and the mean dialysis vintage was 65.8 ± 58.6 months. Serum levels of β 2 ‐microglobulin, TNF‐α, and IL‐6 were compared by paired‐samples t test between the end and the beginning of the study period. Dialysis adequacy, electrolytes, heparin doses, low‐density lipoprotein (LDL), hemoglobin, and albumin levels were also compared. In addition, the performance of the two MCO dialyzers was compared using an independent‐samples t test.

Results

There was a significant decrease in β 2 ‐microglobulin ( p = 0.02), LDL ( p < 0.01), and albumin levels ( p < 0.001) at the end of the study. Dialysis adequacy, hemoglobin, phosphorus, C‐reactive protein, IL‐6, and TNF‐α levels did not change significantly. Among patients receiving standard heparin for anticoagulation, heparin doses had to be increased during MCO membrane use. The performance of the two different dialyzers was not statistically different.

Conclusions

MCO membranes provide clearance of middle‐sized uremic toxins. This effect is most prominent for β 2 ‐microglobulin and does not differ between the two MCO dialyzers studied. MCO membranes may cause some albumin loss, and heparin requirements may increase during their use.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Membranes, ArtificialRenal DialysisKidney Failure, ChronicHumansMiddle AgedFemaleProspective StudiesMalebeta 2-MicroglobulinTumor Necrosis Factor-alphaInterleukin-6Aged

Stichwörter der Autor:innen

MCOdialyzershemodialysismembranesβ2‐microglobulin

Substanzen

Membranes, Artificialbeta 2-MicroglobulinTumor Necrosis Factor-alphaInterleukin-6

Autor:innen und Institutionen

  • Hemodialysis Unit, Rentek Dialysis Center, Istanbul, Turkey.
  • Cerrahpasa Medical Faculty, Nephrology Clinic, Istanbul University-Cerrahpasa, Istanbul, Turkey.

ORCID-Profile: Gurkan Yurteri, Ahmet Murt

Zitieren

APA

Yurteri, G., & Murt, A. (2026). Efficiency and Safety of Different Medium Cut‐Off Membranes in Maintenance Hemodialysis Patients. Seminars in Dialysis. https://doi.org/10.1111/sdi.70017

Vancouver

Yurteri G, Murt A. Efficiency and Safety of Different Medium Cut‐Off Membranes in Maintenance Hemodialysis Patients. Seminars in Dialysis. 2026. doi:10.1111/sdi.70017

BibTeX
@article{Yurteri2026,
  author = {Yurteri, Gurkan and Murt, Ahmet},
  title = {Efficiency and Safety of Different Medium Cut‐Off Membranes in Maintenance Hemodialysis Patients},
  journal = {Seminars in Dialysis},
  year = {2026},
  doi = {10.1111/sdi.70017}
}
Kostenlos starten →