EUVIMEDEUVIMED entdecken
Crossref

Quantitative microbial risk assessment of bioaerosol emissions from squat and bidet toilets during flushing

Wajid Ali, Zhen Hu, Zhe-Ren Tang, Si-Yi Liu, Zaheer Ahmad Nasir, Frederic Coulon, Peng Liu, Cheng Yan

Risk Analysis · 2025

DOI: 10.1111/risa.70000 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Risk Analysis, 2025. Verfasst von Wajid Ali und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Environmental Studies, China University of Geosciences, Wuhan, P. R. China. Hauptthemen laut MEDLINE: Toilet Facilities, Air Microbiology, Bathroom Equipment. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 82 Literaturangaben. Gefördert von: SPF Clean Air Programme, Environmental Microbiology and Human Health Programme.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Bioaerosol emissions during toilet flushing are an often‐overlooked source of potential health risks in shared public facilities. This study systematically investigated the emission characteristics of Staphylococcus aureus and Escherichia coli bioaerosols in washrooms with squat and bidet toilets under varying flushing conditions and ventilation scenarios. Using Monte Carlo simulation–based quantitative microbial risk assessment and sensitivity analysis, the study estimated the disease burden and identified key factors influencing risk. The results showed that squat toilets generated 1.7–2.6 times higher concentrations of S. aureus bioaerosols and 1.2–1.4 times higher concentrations of E. coli bioaerosols compared to bidet toilets. After the first flush, bioaerosol concentrations were 1.3–1.8 times ( S. aureus ) and 1.2–1.4 times ( E. coli ) lower than those observed after the second flush. The second flush released a higher proportion of fine bioaerosol particles (

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Toilet FacilitiesAir MicrobiologyBathroom EquipmentRisk AssessmentAerosolsHumansEscherichia coliStaphylococcus aureusMonte Carlo MethodVentilationAir Pollution, Indoor

Stichwörter der Autor:innen

Monte Carlo simulationbioaerosoldisease burdenquantitative microbial risk assessmentsensitivity analysistoilet

Substanzen

Aerosols

Autor:innen und Institutionen

  • School of Environmental Studies, China University of Geosciences, Wuhan, P. R. China.
  • Wuhan Huzhenyu Environmental Technology Co., Ltd, Wuhan, P. R. China.
  • National Engineering Research Center of Eco-Environment in the Yangtze River Economic Belt, China Three Gorges Corporation, Wuhan, P. R. China.
  • School of Water, Energy and Environment, Cranfield University, Bedfordshire, UK.

Förderung

  • SPF Clean Air Programme
  • Environmental Microbiology and Human Health Programme

Zitieren

APA

Ali, W., Hu, Z., Tang, Z. R., Liu, S. Y., Nasir, Z. A., Coulon, F., Liu, P., & Yan, C. (2025). Quantitative microbial risk assessment of bioaerosol emissions from squat and bidet toilets during flushing. Risk Analysis. https://doi.org/10.1111/risa.70000

Vancouver

Ali W, Hu Z, Tang ZR, Liu SY, Nasir ZA, Coulon F, et al. Quantitative microbial risk assessment of bioaerosol emissions from squat and bidet toilets during flushing. Risk Analysis. 2025. doi:10.1111/risa.70000

BibTeX
@article{Ali2025,
  author = {Ali, Wajid and Hu, Zhen and Tang, Zhe-Ren and Liu, Si-Yi and Nasir, Zaheer Ahmad and Coulon, Frederic and Liu, Peng and Yan, Cheng},
  title = {Quantitative microbial risk assessment of bioaerosol emissions from squat and bidet toilets during flushing},
  journal = {Risk Analysis},
  year = {2025},
  doi = {10.1111/risa.70000}
}
Kostenlos starten →