Human and Deep Learning Predictions of Peripheral Lung Cancer Using a 1.3 mm Video Endoscopic Probe
Respirology · 2025
DOI: 10.1111/resp.70057 ↗Kurz gefasst
Fachartikel in der Zeitschrift Respirology, 2025. Verfasst von Edoardo Amante und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pneumology, Rouen University Hospital, Rouen, France. Hauptthemen laut MEDLINE: Deep Learning, Lung Neoplasms, Bronchoscopy, Endosonography. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background and Objective Iriscope, a 1.3 mm video endoscopic probe introduced through an r‐EBUS catheter, allows for the direct visualisation of small peripheral pulmonary nodules (PPNs). This study assessed the ability of physicians with different levels of experience in bronchoscopy, and the ability of artificial intelligence (AI) to predict the malignant nature of small PPNs during Iriscope peripheral endoscopy.
Methods
Patients undergoing bronchoscopy with r‐EBUS and Iriscope for peripheral PPNs < 20 mm with a definite diagnosis were analysed. Senior and Junior physicians independently interpreted video‐recorded Iriscope sequences, classifying them as tumoral (malignant) or non‐tumoral, blind to the final diagnosis. A deep learning (DL) model was also trained on Iriscope images and tested on a different set of patients for comparison with human interpretation. Diagnostic accuracy, sensitivity, specificity, and F1 score were calculated.
Results
Sixty‐one patients with small PPNs (median size 15 mm, IQR: 11–20 mm) were included. The technique allowed for the direct visualisation of the lesions in all cases. The final diagnosis was cancer for 37 cases and a benign lesion in 24 cases. Senior physicians outperformed junior physicians in recognising tumoral Iriscope images, with a balanced accuracy of 85.4% versus 66.7%, respectively, when compared with the final diagnosis. The DL model outperformed junior physicians with a balanced accuracy of 71.5% but was not superior to senior physicians.
Conclusion
Iriscope could be a valuable tool in PPNs management, especially for experienced operators. Applied to Iriscope images, DL could enhance overall performance of less experienced physicians in diagnosing malignancy. image
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pneumology, Rouen University Hospital, Rouen, France.
- Department of Pulmonary Medicine and Interventional Pulmonology, Catholic University of the Sacred Hearth, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy.
- Faculty of Computer Science, NaDI, University of Namur, Namur, Belgium.
- Department of Pulmonology and Inserm CIC-CRB 1404, Normandie Univ, UNIROUEN, LITIS Lab QuantIF Team EA4108, CHU Rouen, Rouen, France.
ORCID-Profile: Rocco Trisolini, Mathieu Salaün, Samy Lachkar
Zitieren
APA
Amante, E., Ghyselinck, R., Thiberville, L., Trisolini, R., Guisier, F., Delchevalerie, V., Dumas, B., Frénay, B., Duparc, I., Mazellier, N., Farhi, C., Jubert, C., Salaün, M., & Lachkar, S. (2025). Human and Deep Learning Predictions of Peripheral Lung Cancer Using a 1.3 mm Video Endoscopic Probe. Respirology. https://doi.org/10.1111/resp.70057
Vancouver
Amante E, Ghyselinck R, Thiberville L, Trisolini R, Guisier F, Delchevalerie V, et al. Human and Deep Learning Predictions of Peripheral Lung Cancer Using a 1.3 mm Video Endoscopic Probe. Respirology. 2025. doi:10.1111/resp.70057
BibTeX
@article{Amante2025,
author = {Amante, Edoardo and Ghyselinck, Robin and Thiberville, Luc and Trisolini, Rocco and Guisier, Florian and Delchevalerie, Valentin and Dumas, Bruno and Frénay, Benoît and Duparc, Inès and Mazellier, Nicolas and Farhi, Cecile and Jubert, Christophe and Salaün, Mathieu and Lachkar, Samy},
title = {Human and Deep Learning Predictions of Peripheral Lung Cancer Using a 1.3 mm Video Endoscopic Probe},
journal = {Respirology},
year = {2025},
doi = {10.1111/resp.70057}
}
EUVIMED