DUETS for Light's in separating exudate from transudate
Respirology · 2024
DOI: 10.1111/resp.14780 ↗Kurz gefasst
Fachartikel in der Zeitschrift Respirology, 2024. Verfasst von Astrid Gardiner und 9 weiteren Autor:innen. Beteiligte Einrichtung: Division of Respiratory and Critical Care Medicine, National University Hospital, Singapore, Singapore. Hauptthemen laut MEDLINE: Exudates and Transudates, Pleural Effusion, Ultrasonography. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 24 Literaturangaben.
Abstract (Originalsprache)
Background
Fifty years since its inception, Light's criteria have aided in classifying pleural effusions (PEs) as exudates if 1 or more criteria are met. Thoracic ultrasound (US) emerges as a non‐invasive technique for point of care use especially if pleural procedures are contemplated.
Objective
We aimed to develop a score based on radiological and US features that could separate exudates from transudates without serum and pleural fluid biochemical tests necessary for Light's criteria.
Methods
A prospective review of consecutive patients with PE who underwent thoracocentesis was performed. CXRs were evaluated for laterality followed by US for echogenicity, pleural nodularity, thickening and septations. PE was classified as exudate or transudate according to Light's criteria and corroborated with albumin gradient. A score combining radiological and US features was developed.
Results
We recruited 201 patients with PE requiring thoracocentesis. Mean age was 64 years, 51% were females, 164 (81.6%) were exudates, and 37 (18.4%) were transudates. Assigning 1‐point for D iaphragmatic nodularity, U nilateral, E chogenicity, Pleural T hickening and S eptations, DUETS ranged from 1 to 5. DUETS ≥2 indicated high likelihood for exudate (PPV 98.8%, NPV 100%) with 1% misclassification versus 6.9% using Light's criteria ( p < 0.001).
Conclusion
DUETS separated exudates from transudates with good accuracy, and could obviate paired serum and pleural fluid tests necessary for Light's criteria computation. Our study reflected real world practice where DUETS performed better than Light's criteria for PE that arose from more than one disease processes, and in the evaluation of patients with PE who have received diuretics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Respiratory and Critical Care Medicine, National University Hospital, Singapore, Singapore.
- Department of Sleep and Respiratory Medicine, Royal Prince Alfred Hospital, Sydney, Australia.
- Yong Loo Lin School of Medicine, National University Hospital, Singapore, Singapore.
- Biostatistics Unit, Yong Loo Lin School of Medicine, National University Hospital, Singapore, Singapore.
- Pleural Medicine Unit, Department of Internal Medicine, Arnau de Vilanova University Hospital, University of Lleida, Lleida, Spain.
- Pleural Medicine Unit, Institute of Respiratory Health, Perth, Australia.
ORCID-Profile: Astrid Gardiner, Jose Porcel, Y C Gary Lee, Pyng Lee
Zitieren
APA
Gardiner, A., Ling, R., Chan, Y. H., Porcel, J., Lee, Y. C. G., Teoh, C. M., Liew, M. F., Kapur, J., Low, S. P., & Lee, P. (2024). DUETS for Light's in separating exudate from transudate. Respirology. https://doi.org/10.1111/resp.14780
Vancouver
Gardiner A, Ling R, Chan YH, Porcel J, Lee YCG, Teoh CM, et al. DUETS for Light's in separating exudate from transudate. Respirology. 2024. doi:10.1111/resp.14780
BibTeX
@article{Gardiner2024,
author = {Gardiner, Astrid and Ling, Ryan and Chan, Yiong-Huak and Porcel, Jose and Lee, Y C Gary and Teoh, Chia-Meng and Liew, Mei-Fong and Kapur, Jeevesh and Low, Seow-Ping and Lee, Pyng},
title = {DUETS for Light's in separating exudate from transudate},
journal = {Respirology},
year = {2024},
doi = {10.1111/resp.14780}
}
EUVIMED