Comparison of the specimen quality of endobronchial ultrasound‐guided intranodal forceps biopsy using standard‐sized forceps versus mini forceps for lung cancer: A prospective study
Respirology · 2024
DOI: 10.1111/resp.14659 ↗Kurz gefasst
Fachartikel in der Zeitschrift Respirology, 2024. Verfasst von Toshiyuki Nakai und 20 weiteren Autor:innen. Beteiligte Einrichtung: Department of Respiratory Medicine, Graduate School of Medicine, Osaka Metropolitan University, Osaka, Japan. Hauptthemen laut MEDLINE: Lung Neoplasms, Lymphadenopathy. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: National Cancer Center Research and Development Fund.
Abstract (Originalsprache)
Background and Objective Endobronchial ultrasound‐guided transbronchial needle aspiration (EBUS‐TBNA) is a diagnostic procedure with adequate performance; however, its ability to provide specimens of sufficient quality and quantity for treatment decision‐making in advanced‐stage lung cancer may be limited, primarily due to blood contamination. The use of a 0.96‐mm miniforceps biopsy (MFB) permits true histological sampling, but the resulting small specimens are unsuitable for the intended applications. Therefore, we introduced a 1.9‐mm standard‐sized forceps biopsy (SFB) and compared its utility to that of MFB.
Methods
We prospectively enrolled patients from three institutions who presented with hilar/mediastinal lymphadenopathy and suspected advanced‐stage lung cancer, or those who were already diagnosed but required additional tissue specimens for biomarker analysis. Each patient underwent MFB followed by SFB three or four times through the tract created by TBNA using a 22‐gauge needle on the same lymph node (LN). Two pathologists assessed the quality and size of each specimen using a virtual slide system, and diagnostic performance was compared between the MFB and SFB groups.
Results
Among the 60 enrolled patients, 70.0% were diagnosed with adenocarcinoma. The most frequently targeted sites were the lower paratracheal LNs, followed by the interlobar LNs. The diagnostic yields of TBNA, MFB and SFB were 91.7%, 93.3% and 96.7%, respectively. The sampling rate of high‐quality specimens was significantly higher in the SFB group. Moreover, the mean specimen size for SFB was three times larger than for MFB.
Conclusion
SFB is useful for obtaining sufficient qualitative and quantitative specimens.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Respiratory Medicine, Graduate School of Medicine, Osaka Metropolitan University, Osaka, Japan.
- Department of Endoscopy, Respiratory Endoscopy Division, National Cancer Center Hospital, Tokyo, Japan.
- Department of Thoracic Oncology, National Cancer Center Hospital, Tokyo, Japan.
- Department of Respiratory Medicine, Izumi City General Hospital, Osaka, Japan.
- Department of Pathology, Graduate School of Medicine, Osaka Metropolitan University, Osaka, Japan.
- Laboratory of Statistics, Graduate School of Medicine, Osaka Metropolitan University, Osaka, Japan.
ORCID-Profile: Toshiyuki Nakai, Yuji Matsumoto, Atsushi Miyamoto, Hideaki Furuse, Keigo Uchimura
Förderung
- National Cancer Center Research and Development Fund
Zitieren
APA
Nakai, T., Matsumoto, Y., Ueda, T., Kuwae, Y., Tanaka, S., Miyamoto, A., Matsumoto, Y., Sawa, K., Sato, K., Yamada, K., Watanabe, T., Asai, K., Furuse, H., Uchimura, K., Imabayashi, T., Uenishi, R., Fukui, M., Tanaka, H., Ohsawa, M., …, & Tsuchida, T. (2024). Comparison of the specimen quality of endobronchial ultrasound‐guided intranodal forceps biopsy using standard‐sized forceps versus mini forceps for lung cancer: A prospective study. Respirology. https://doi.org/10.1111/resp.14659
Vancouver
Nakai T, Matsumoto Y, Ueda T, Kuwae Y, Tanaka S, Miyamoto A, et al. Comparison of the specimen quality of endobronchial ultrasound‐guided intranodal forceps biopsy using standard‐sized forceps versus mini forceps for lung cancer: A prospective study. Respirology. 2024. doi:10.1111/resp.14659
BibTeX
@article{Nakai2024,
author = {Nakai, Toshiyuki and Matsumoto, Yuji and Ueda, Takahiro and Kuwae, Yuko and Tanaka, Sayaka and Miyamoto, Atsushi and Matsumoto, Yoshiya and Sawa, Kenji and Sato, Kanako and Yamada, Kazuhiro and Watanabe, Tetsuya and Asai, Kazuhisa and Furuse, Hideaki and Uchimura, Keigo and Imabayashi, Tatsuya and Uenishi, Riki and Fukui, Mitsuru and Tanaka, Hidenori and Ohsawa, Masahiko and Kawaguchi, Tomoya and Tsuchida, Takaaki},
title = {Comparison of the specimen quality of endobronchial ultrasound‐guided intranodal forceps biopsy using standard‐sized forceps versus mini forceps for lung cancer: A prospective study},
journal = {Respirology},
year = {2024},
doi = {10.1111/resp.14659}
}
EUVIMED