The Electrocardiogram‐Based Phase Adjustment Task ( PAT ‐ ECG ): An Open‐Access Laboratory Test of Cardiac Interoceptive Accuracy
Psychophysiology · 2026-10 · 63 (10)
DOI: 10.1111/psyp.70415 ↗Kurz gefasst
Fachartikel in der Zeitschrift Psychophysiology, online erschienen am 30.09.2026. Verfasst von James Hodgetts und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Sport Science, Institute for the Psychology of Elite Performance (IPEP), Bangor University, Bangor, UK. Hauptthemen laut MEDLINE: Interoception, Electrocardiography, Heart Rate. Die Arbeit nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Interoceptive accuracy plays a central role in theories of emotion, and atypical interoceptive accuracy is increasingly recognized as a feature in the pathophysiology of multiple clinical and subclinical conditions. However, existing methods for assessing interoceptive accuracy have limitations that may constrain research progress. This study presents the first electrocardiogram‐based implementation of the phase adjustment task (PAT‐ECG), a rigorous measure of cardiac interoceptive accuracy, and provides the materials and experimental code for its use. Similar to existing PAT implementations, the task presents tones at each participant's heart rate and requires them to adjust the phase of the tone to synchronize it with their heartbeats. Crucially, this implementation replaces the photoplethysmographic signal used in previous implementations with ECG, enabling superior temporal resolution and more precise triggering via the R‐wave peak. We additionally introduce a novel phase‐delay timing procedure during task execution and explore new data‐analytic approaches. Data from 91 participants are used to demonstrate the task, and eight options for classifying individuals as interoceptive or non‐interoceptive are evaluated. Seventeen percent of participants were classified as interoceptive at rest via PAT‐ECG. Findings extend evidence for distinct variable‐period and fixed‐period interoceptive pathways. Weighting trials by confidence ratings further influenced interoceptive accuracy scores. The original PAT represented a significant advancement in cardiac interoceptive accuracy assessment; this open‐access ECG‐based implementation extends PAT methodological precision, providing an even more rigorous assessment tool for further advancing interoception theories and research.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Sport Science, Institute for the Psychology of Elite Performance (IPEP), Bangor University, Bangor, UK.
- School of Sport, Exercise and Rehabilitation Sciences, University of Birmingham, Birmingham, UK.
- School of Psychology, University of Surrey, London, UK.
ORCID-Profile: James Hodgetts, Germano Gallicchio, Christopher Ring, Jennifer Murphy, Andrew Cooke
Zitieren
APA
Hodgetts, J., Gallicchio, G., Mckiernan, S., Ring, C., Murphy, J., & Cooke, A. (2026). The Electrocardiogram‐Based Phase Adjustment Task ( PAT ‐ ECG ): An Open‐Access Laboratory Test of Cardiac Interoceptive Accuracy. Psychophysiology, 63(10). https://doi.org/10.1111/psyp.70415
Vancouver
Hodgetts J, Gallicchio G, Mckiernan S, Ring C, Murphy J, Cooke A. The Electrocardiogram‐Based Phase Adjustment Task ( PAT ‐ ECG ): An Open‐Access Laboratory Test of Cardiac Interoceptive Accuracy. Psychophysiology. 2026;63(10). doi:10.1111/psyp.70415
BibTeX
@article{Hodgetts2026,
author = {Hodgetts, James and Gallicchio, Germano and Mckiernan, Shaun and Ring, Christopher and Murphy, Jennifer and Cooke, Andrew},
title = {The Electrocardiogram‐Based Phase Adjustment Task ( PAT ‐ ECG ): An Open‐Access Laboratory Test of Cardiac Interoceptive Accuracy},
journal = {Psychophysiology},
year = {2026},
volume = {63},
number = {10},
doi = {10.1111/psyp.70415}
}
EUVIMED