EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Individual Differences in Heartbeat‐Tone Synchronicity Judgments Suggest the Two‐Alternative Heartbeat Detection Task Is a Poor Test of Cardiac Interoceptive Accuracy and Insight

Kiera Louise Adams, Ren Palmer, Jonathan M Bird, David Plans, Adam Cunningham, Davide Morelli, Tom Piercy, Ria Spooner, Rhea Clemente, Nerea Irigoras Izagirre, Elisa Fernandez Fueyo, Dawn Watling und 8 weitere

Psychophysiology · 2026-05 · 63 (5)

DOI: 10.1111/psyp.70310 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Psychophysiology, online erschienen am 13.05.2026. Verfasst von Kiera Louise Adams und 19 weiteren Autor:innen. Beteiligte Einrichtung: Department of Experimental Psychology, University of Oxford, Oxford, UK. Hauptthemen laut MEDLINE: Interoception, Heart Rate, Individuality, Judgment. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Oxford Medical Sciences Graduate School Studentship (Clarendon Fund in partnership with the University College Award and the Experimental Psychol…, NIHR University College London Hospitals Biomedical Research Centre, ESRC South East Network for Social Sciences (SeNSS) PhD studentship.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Despite concerns regarding its validity, the two‐alternative forced‐choice heartbeat detection task (2AFC‐HDT) is a frequently used measure of cardiac interoceptive accuracy. In this task, participants must decide whether a series of tones occur synchronously with their heartbeats. One series of tones is predefined by the researcher as synchronous with heartbeats, and one series is predefined as asynchronous. The 2AFC‐HDT may result in individuals judged to be not interoceptive when they are, either if participants perceive their heartbeats as occurring synchronously with tones predefined as asynchronous rather than synchronous with their heartbeats, or if they do not perceive either set of tones as synchronous. Currently, there is little data on the proportion of participants this may affect. We addressed this using data from the Phase Adjustment Task (PAT) – a measure of cardiac interoceptive accuracy that determines if, and when in the cardiac cycle, a participant can perceive their heartbeat. The timing of heartbeat perception in 43 interoceptive participants was compared to the timing of synchronous and asynchronous tones used in the 2AFC‐HDT, assuming temporal precision of 50, 100, and 150 ms. Results suggest that between 53.5%–97.7% of delay‐based interoceptive individuals perceive heartbeats at a delay that does not correspond to the typical asynchronous or synchronous delays used to present tones on the 2AFC‐HDT. These issues suggest that the 2AFC‐HDT (or other measures that make assumptions about perceived timing of heartbeats) should not be used to measure cardiac interoceptive accuracy, or cardiac interoceptive insight (also known as awareness or metacognition).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

InteroceptionHeart RateIndividualityJudgmentAuditory PerceptionHumansFemaleMaleAdultYoung Adult

Stichwörter der Autor:innen

HDTInteroceptioncardioceptionheartbeat detection taskinteroceptive accuracyinteroceptive insight

Autor:innen und Institutionen

  • Department of Experimental Psychology, University of Oxford, Oxford, UK.
  • Olga Tennison Autism Research Centre, School of Psychology and Public Health, La Trobe University, Bundoora, Australia.
  • Department of Psychology, University of Surrey, Surrey, UK.
  • Department of Targeted Intervention, University College London, London, UK.
  • Department of Psychology, Royal Holloway, University of London, Egham, UK.
  • Huma Therapeutics Ltd, London, UK.

Förderung

  • University of Oxford Medical Sciences Graduate School Studentship (Clarendon Fund in partnership with the University College Award and the Experimental Psychol…
  • NIHR University College London Hospitals Biomedical Research Centre
  • ESRC South East Network for Social Sciences (SeNSS) PhD studentship
  • The Medical Research Council (UKRI)
  • Royal Holloway, University of London
  • LIDo/BBSRC Studentship
  • Center of Alcohol and Substance Use Studies pilot grant at Rutgers University
  • National Fund for Scientific Research of Belgium

Zitieren

APA

Adams, K. L., Palmer, R., Bird, J. M., Plans, D., Cunningham, A., Morelli, D., Piercy, T., Spooner, R., Clemente, R., Izagirre, N. I., Fueyo, E. F., Watling, D., Brewer, R., Budworth, G., Cocirla, D., Leganes-Fonteneau, M., Todd, J., Aspell, J. E., Bird, G., & Murphy, J. (2026). Individual Differences in Heartbeat‐Tone Synchronicity Judgments Suggest the Two‐Alternative Heartbeat Detection Task Is a Poor Test of Cardiac Interoceptive Accuracy and Insight. Psychophysiology, 63(5). https://doi.org/10.1111/psyp.70310

Vancouver

Adams KL, Palmer R, Bird JM, Plans D, Cunningham A, Morelli D, et al. Individual Differences in Heartbeat‐Tone Synchronicity Judgments Suggest the Two‐Alternative Heartbeat Detection Task Is a Poor Test of Cardiac Interoceptive Accuracy and Insight. Psychophysiology. 2026;63(5). doi:10.1111/psyp.70310

BibTeX
@article{Adams2026,
  author = {Adams, Kiera Louise and Palmer, Ren and Bird, Jonathan M and Plans, David and Cunningham, Adam and Morelli, Davide and Piercy, Tom and Spooner, Ria and Clemente, Rhea and Izagirre, Nerea Irigoras and Fueyo, Elisa Fernandez and Watling, Dawn and Brewer, Rebecca and Budworth, Gemma and Cocirla, Dorina and Leganes-Fonteneau, Mateo and Todd, Jennifer and Aspell, Jane E and Bird, Geoffrey and Murphy, Jennifer},
  title = {Individual Differences in Heartbeat‐Tone Synchronicity Judgments Suggest the Two‐Alternative Heartbeat Detection Task Is a Poor Test of Cardiac Interoceptive Accuracy and Insight},
  journal = {Psychophysiology},
  year = {2026},
  volume = {63},
  number = {5},
  doi = {10.1111/psyp.70310}
}
Kostenlos starten →