No Single Best Pipeline: Multiverse Analysis of EEG Preprocessing for N‐Back Working Memory Tasks
Psychophysiology · 2025
DOI: 10.1111/psyp.70197 ↗Kurz gefasst
Fachartikel in der Zeitschrift Psychophysiology, 2025. Verfasst von Haijing Huang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Discipline of Psychiatry and Mental Health, Faculty of Medicine and Health, School of Clinical Medicine, University of New South Wales, Sydney, New S…. Hauptthemen laut MEDLINE: Electroencephalography, Memory, Short-Term, Evoked Potentials, Major Depressive Disorder. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 93 Literaturangaben.
Abstract (Originalsprache)
Working memory (WM) involves temporary information maintenance and manipulation, widely assessed using n‐back tasks. This study systematically compared forty‐three electroencephalography (EEG) preprocessing pipelines, varying in high‐pass filtering, low‐pass filtering, Independent Component Analysis, and re‐referencing methods, to evaluate their impact on event‐related potentials (ERP) during the n‐back (2‐back and 3‐back) task across three previously published datasets with a total of 164 participants. The primary outcome was ERP data quality of the P300 measured at the Pz across preprocessing pipelines. A composite signal quality score combining N200 at Fz and P300 and P200 at Pz was evaluated across all pipelines as a secondary analysis. Data quality was evaluated across three dimensions: target trials signal quality, target‐nontarget difference waveforms, and group‐level signal‐to‐noise ratios (SNR) consistency between major depressive disorder (MDD) and health control participants. No preprocessing pipeline performed optimally across all assessment dimensions. The combination of 0.5 Hz high‐pass filtering, 100 Hz low‐pass filtering, and REST referencing showed strengths in SNR optimization, ranking highly for target trial quality, target‐nontarget difference waveforms, and group‐level analyses. However, other pipelines demonstrated advantages for amplitude preservation or measurement reliability (standardized measurement error). High‐pass filtering and referencing choices substantially influenced ERP outcomes at both individual and group levels. 0.5 Hz high‐pass filtering alone performed optimally for target versus non‐target discrimination. This multiverse analysis demonstrates that preprocessing parameters should be tailored to specific research objectives, as methodological decisions influence EEG data quality and interpretation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Discipline of Psychiatry and Mental Health, Faculty of Medicine and Health, School of Clinical Medicine, University of New South Wales, Sydney, New South Wales, Australia.
- Black Dog Institute, Sydney, New South Wales, Australia.
Zitieren
APA
Huang, H., Moffa, A. H., Loo, C., & Nikolin, S. (2025). No Single Best Pipeline: Multiverse Analysis of EEG Preprocessing for N‐Back Working Memory Tasks. Psychophysiology. https://doi.org/10.1111/psyp.70197
Vancouver
Huang H, Moffa AH, Loo C, Nikolin S. No Single Best Pipeline: Multiverse Analysis of EEG Preprocessing for N‐Back Working Memory Tasks. Psychophysiology. 2025. doi:10.1111/psyp.70197
BibTeX
@article{Huang2025,
author = {Huang, Haijing and Moffa, Adriano H and Loo, Colleen and Nikolin, Stevan},
title = {No Single Best Pipeline: Multiverse Analysis of EEG Preprocessing for N‐Back Working Memory Tasks},
journal = {Psychophysiology},
year = {2025},
doi = {10.1111/psyp.70197}
}
EUVIMED