Randomisierte kontrollierte Studie in der Zeitschrift Psychophysiology, 2025. Verfasst von Mona Malekahmad und 3 weiteren Autor:innen. Beteiligte Einrichtung: Monash Neuromodulation Research Unit (MNRU), Department of Physiotherapy, Monash University, Melbourne, Victoria, Australia. Hauptthemen laut MEDLINE: Transcranial Direct Current Stimulation, Motor Cortex, Pyramidal Tracts, Evoked Potentials, Motor. Die Arbeit nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The mechanism underlying transcranial pulsed current stimulation (tPCS) as a non‐invasive neuromodulation technique has garnered considerable attention in recent years. However, the effects of anodal tPCS (a‐tPCS) at low frequencies remain unexplored. This study aimed to investigate the a‐tPCS effects at 0.5, 1, 3, and 5 Hz on cortical outcomes and its adverse side effects. This double‐blinded, randomized, counterbalanced crossover trial included 18 healthy young participants who completed five experimental sessions with 2 mA of a‐tPCS for 20 min in a randomized order of frequencies (0.5, 1, 3, and 5 Hz). Single‐pulse and paired‐pulse transcranial magnetic stimulation (TMS) on the left primary motor cortex (M1) was delivered before and immediately after the stimulation at rest. Sessions were spaced at least 48 h apart to minimize carry‐over effects. The results indicated that a single session of a‐tPCS at frequencies of 1, 3, and 5 Hz significantly ( p < 0.05) enhanced corticospinal excitability (CSE), while 0.5 Hz decreased CSE compared to sham stimulation. The CSE changes at 1 and 5 Hz were associated with increased intracortical facilitation (ICF), with reduced adverse effects observed at higher frequencies. In contrast, the cortical effects of 0.5 Hz were linked to increased short intracortical inhibition (SICI) with minimal side effects. However, all frequencies except 0.5 Hz were associated with phosphenes or flashing lights during stimulation. Given the similar effects of a‐tPCS with other pulsatile current stimulation, it is plausible that tPCS could serve as a complementary or superior alternative to TMS, particularly for at‐risk and diverse patient populations. However, this claim needs further comparative studies before suggesting clinical superiority for epilepsy and neuro‐rehabilitation. Furthermore, like other neuromodulation techniques, tPCS shows potential as an affordable, home‐based treatment option. Further research is needed to establish the efficacy of tPCS relative to TMS methodologies through rigorous experimental testing.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Monash Neuromodulation Research Unit (MNRU), Department of Physiotherapy, Monash University, Melbourne, Victoria, Australia.
- Discipline of Physiotherapy, Federation University, Ballarat, Victoria, Australia.
ORCID-Profile: Mona Malekahmad, Shapour Jaberzadeh
Zitieren
APA
Malekahmad, M., Frazer, A., Zoghi, M., & Jaberzadeh, S. (2025). Investigating the Effects of Anodal Transcranial Pulsed Current Stimulation at Low Frequencies (0.5 to 5 Hz) on Corticospinal and Corticocortical Excitability. Psychophysiology. https://doi.org/10.1111/psyp.70092
Vancouver
Malekahmad M, Frazer A, Zoghi M, Jaberzadeh S. Investigating the Effects of Anodal Transcranial Pulsed Current Stimulation at Low Frequencies (0.5 to 5 Hz) on Corticospinal and Corticocortical Excitability. Psychophysiology. 2025. doi:10.1111/psyp.70092
BibTeX
@article{Malekahmad2025,
author = {Malekahmad, Mona and Frazer, Ashlyn and Zoghi, Maryam and Jaberzadeh, Shapour},
title = {Investigating the Effects of Anodal Transcranial Pulsed Current Stimulation at Low Frequencies (0.5 to 5 Hz) on Corticospinal and Corticocortical Excitability},
journal = {Psychophysiology},
year = {2025},
doi = {10.1111/psyp.70092}
}
EUVIMED