EUVIMEDEUVIMED entdecken
Crossref

Usefulness of donor breast sterilization with slightly acidic electrolyzed water to reduce bacterial count in human milk

Kumiko Miura iD, Miori Tanaka, Kasumi Takayama, Mizuho Ito, Noriko Mizuno, Katsumi Mizuno iD

Pediatrics International · 2025-01 · 67 (1)

DOI: 10.1111/ped.70223 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pediatrics International, online erschienen am 14.10.2025. Verfasst von Kumiko Miura und 5 weiteren Autor:innen. Beteiligte Einrichtung: The Nippon Foundation Human Milk Bank, Tokyo, Japan. Hauptthemen laut MEDLINE: Milk, Human, Milk Banks, Bacterial Load, Sterilization. Die Arbeit nennt 34 Literaturangaben. Gefördert von: Morinaga Milk Industry.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Human milk banks (HMBs) face challenges in minimizing the disposal of donated human milk (HM). One of the primary reasons for HM disposal in HMBs is samples exceeding the upper limit for the total bacterial count. Pre‐expression breast cleaning with tap water is mandated in the guidelines for HMBs as a key hygiene practice for reducing the amount of disposed HM. The primary objective of this study was to investigate the effectiveness of breast cleaning with slightly acidic electrolyzed water (SAEW) for reducing HM contamination at the pre‐expression stage.

Methods

Twenty‐six mothers whose donated HMs did not meet HMB bacterial standards, despite pump changes and intensive hygiene instructions, were included. Over 3 weeks, participants sprayed their breast surfaces with SAEW before expression. Bacterial counts and macronutrients in HM expressed with and without SAEW were compared.

Results

The total bacterial count in HM decreased significantly from 2.9 × 10 6 colony‐forming units (CFU)/mL to 2.3 × 10 3 CFU/mL when SAEW was used. The prevalence of mothers whose HM exceeded the bacterial standard decreased from 84.6% to 10% with SAEW use. However, no reduction in spore‐forming bacteria, such as Bacillus cereus, was found in this study. In addition, no significant changes in macronutrients or adverse skin reactions were observed.

Conclusion

The use of SAEW for breast cleaning could be an effective and safe hygiene solution for minimizing the need to discard valuable donated HM, especially for donors whose bacterial counts remained high despite hygiene instructions provided by HMB staff.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Milk, HumanMilk BanksBacterial LoadSterilizationWaterHumansFemaleAdultBreast Milk ExpressionHygiene

Stichwörter der Autor:innen

Milk banksbreast milk expressiondecontaminationhuman milkslightly acidic electrolyzed water

Substanzen

Water

Autor:innen und Institutionen

  • The Nippon Foundation Human Milk Bank, Tokyo, Japan.
  • Faculty of Medicine, Oita University, Yufu-shi, Oita, Japan.
  • Japan Human Milk Bank Association, Tokyo, Japan.
  • Department of Pediatrics, Showa University of Medicine, Tokyo, Japan.

ORCID-Profile: Kumiko Miura, Katsumi Mizuno

Förderung

  • Morinaga Milk Industry

Zitieren

APA

Miura, K., Tanaka, M., Takayama, K., Ito, M., Mizuno, N., & Mizuno, K. (2025). Usefulness of donor breast sterilization with slightly acidic electrolyzed water to reduce bacterial count in human milk. Pediatrics International, 67(1). https://doi.org/10.1111/ped.70223

Vancouver

Miura K, Tanaka M, Takayama K, Ito M, Mizuno N, Mizuno K. Usefulness of donor breast sterilization with slightly acidic electrolyzed water to reduce bacterial count in human milk. Pediatrics International. 2025;67(1). doi:10.1111/ped.70223

BibTeX
@article{Miura2025,
  author = {Miura, Kumiko and Tanaka, Miori and Takayama, Kasumi and Ito, Mizuho and Mizuno, Noriko and Mizuno, Katsumi},
  title = {Usefulness of donor breast sterilization with slightly acidic electrolyzed water to reduce bacterial count in human milk},
  journal = {Pediatrics International},
  year = {2025},
  volume = {67},
  number = {1},
  doi = {10.1111/ped.70223}
}
Kostenlos starten →