Fachartikel in der Zeitschrift Pediatric Anesthesia, 2024. Verfasst von Amanda R Scharenbrock und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, SMPH, University of Wisconsin-Madison, Madison, Wisconsin, USA. Hauptthemen laut MEDLINE: Anesthetics, Inhalation, Electron Transport Complex I, Drosophila melanogaster, Sevoflurane. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National institute of health.
Abstract (Originalsprache)
Background
Individuals with mitochondrial defects, especially those in Complex I of the electron transport chain, exhibit behavioral hypersensitivity and toxicity to volatile anesthetics. In Drosophila melanogaster , mutation of ND23 ( NDUFS8 in mammals), which encodes a subunit of the matrix arm of Complex I, sensitizes flies to toxicity from isoflurane but not an equipotent dose of sevoflurane. Also, in ND23 flies, both anesthetics activate expression of stress response genes, but to different extents. Here, we investigated the generality of these findings by examining flies mutant for ND2 ( ND2 in mammals), which encodes a subunit of the membrane arm of Complex I.
Methods
The serial anesthesia array was used to expose ND2 del1 and ND23 60114 flies to precise doses of isoflurane, sevoflurane, and oxygen. Behavioral sensitivity was assessed by a climbing assay and toxicity by percent mortality within 24 h of exposure. Changes in expression were determined by qRT‐PCR of RNA isolated from heads at 0.5 h after anesthetic exposure.
Results
Unlike ND23 60114 , ND2 del1 did not affect behavioral sensitivity to isoflurane or sevoflurane. Furthermore, sevoflurane in hyperoxia as well as anoxia caused mortality of ND2 del1 but not ND23 60114 flies. Finally, the mutations had different effects on induction of stress response gene expression by the anesthetics.
Conclusion
Mutations in different arms of Complex I resulted in different behavioral sensitivities and toxicities to isoflurane and sevoflurane, indicating that (i) the anesthetics have mechanisms of action that involve arms of Complex I to different extents and (ii) the lack of behavioral hypersensitivity does not preclude susceptibility to anesthetic toxicity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Anesthesiology, SMPH, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Department of Medical Genetics, SMPH, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Laboratory of Genetics, CALS, University of Wisconsin-Madison, Madison, Wisconsin, USA.
ORCID-Profile: Misha Perouansky
Förderung
- National institute of health
Zitieren
APA
Scharenbrock, A. R., Borchardt, L. A., Olufs, Z. P. G., Wassarman, D. A., & Perouansky, M. (2024). Links between mutations in functionally separate arms of mitochondrial complex I and responses to volatile anesthetics. Pediatric Anesthesia. https://doi.org/10.1111/pan.14999
Vancouver
Scharenbrock AR, Borchardt LA, Olufs ZPG, Wassarman DA, Perouansky M. Links between mutations in functionally separate arms of mitochondrial complex I and responses to volatile anesthetics. Pediatric Anesthesia. 2024. doi:10.1111/pan.14999
BibTeX
@article{Scharenbrock2024,
author = {Scharenbrock, Amanda R and Borchardt, Luke A and Olufs, Zachariah P G and Wassarman, David A and Perouansky, Misha},
title = {Links between mutations in functionally separate arms of mitochondrial complex I and responses to volatile anesthetics},
journal = {Pediatric Anesthesia},
year = {2024},
doi = {10.1111/pan.14999}
}
EUVIMED