A prospective comparison of invasive and non‐invasive blood pressure in children undergoing cardiac catheterization
Pediatric Anesthesia · 2023
DOI: 10.1111/pan.14723 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Pediatric Anesthesia, 2023. Verfasst von Richard Beringer und 4 weiteren Autor:innen. Beteiligte Einrichtung: Bristol Royal Hospital for Children, Bristol, UK. Hauptthemen laut MEDLINE: Blood Pressure Determination, Hypotension. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 18 Literaturangaben.
Themen: Kinderkrankenpflege
Abstract (Originalsprache)
Background
Blood pressure measurement is a standard of monitoring during general anesthesia. Invasive measurement is considered the gold standard but is less commonly used than non‐invasive. Automated oscillometric blood pressure devices measure the mean arterial pressure (MAP) and use an algorithm to determine the systolic and diastolic pressures. Few devices have been validated in children, particularly during anesthesia. Few studies have assessed the agreement between invasive and non‐invasive blood pressure measurements in children.
Methods
This was a multi‐center prospective observational study of children under 16 years undergoing cardiac catheterization with general anesthesia. Paired invasive and non‐invasive blood pressure measurements were recorded for each patient during stable periods of the procedure. Correlation within and between sites was assessed with Pearson's correlation coefficient, and agreement was examined using Bland–Altman methodology to determine bias. Agreement during episodes of hypotension and for age and weight was also determined. Bias greater than 5 mmHg and standard deviation greater than 8 mmHg was considered clinically significant. The primary end point was agreement of MAP measurements.
Results
A total of 683 paired blood pressure values were collected from 254 children in three pediatric hospitals. Median [IQR] age and weight were 3 [1–7] years and 13.9 [8–23] Kg. The overall bias (SD) for mean arterial pressure values was 7.2 (11.4) mmHg. During hypotension (190 readings), the bias (SD) was 15 (11.0) mmHg. The non‐invasive MAP was frequently higher than invasive MAP during infancy, and lower in older children.
Conclusion
Automated oscillometric blood pressure measurement is unreliable in anesthetized children during cardiac catheterization. Invasive pressure measurement should be considered for high‐risk cases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Bristol Royal Hospital for Children, Bristol, UK.
- Birmingham Children's Hospital, Birmingham, UK.
- University of the West of England, Bristol, UK.
ORCID-Profile: Tim Murphy, Paul White
Zitieren
APA
Beringer, R., Keith, A., Jones, E., Murphy, T., & White, P. (2023). A prospective comparison of invasive and non‐invasive blood pressure in children undergoing cardiac catheterization. Pediatric Anesthesia. https://doi.org/10.1111/pan.14723
Vancouver
Beringer R, Keith A, Jones E, Murphy T, White P. A prospective comparison of invasive and non‐invasive blood pressure in children undergoing cardiac catheterization. Pediatric Anesthesia. 2023. doi:10.1111/pan.14723