Air Embolism During Cryoballoon Ablation for Atrial Fibrillation Under Different Respiratory Management Strategies
Pacing and Clinical Electrophysiology · 07.11.2026
DOI: 10.1111/pace.70498 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Pacing and Clinical Electrophysiology, online erschienen am 07.11.2026. Verfasst von Hidehira Fukaya und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Kitasato University School of Medicine, Kanagawa, Japan. Die Arbeit nennt 15 Literaturangaben.
Abstract (Originalsprache)
Background
Coronary air embolism is a rare but potentially fatal complication during catheter ablation for atrial fibrillation (AF). Use of large‐bore sheaths, such as those required for balloon‐based catheter ablation, in the setting of unstable respiratory control may increase the risk.
Methods
We retrospectively evaluated consecutive patients who underwent first‐time cryoballoon ablation (CBA) for AF from January 2017 to December 2024. Patients were divided into two groups according to respiratory management strategy: adaptive servo‐ventilation (ASV, n = 266) and laryngeal mask with mechanical ventilation (LM, n = 225). The incidence of complications was compared, with a primary focus on air embolism.
Results
A total of 491 patients (median age 68 years, 71.3% male) were included. Coronary air embolism occurred in 5 patients (1.9%) in the ASV group and in none of the patients in the LM group (absolute risk difference, 1.9%; 95% CI, −0.1% to 4.3%; p = 0.066). In one patient with coronary air embolism, brain MRI performed on the day of the procedure incidentally revealed an asymptomatic acute cerebral embolic lesion. Other complications included two cases of cardiac tamponade in the ASV group and two cases of transient phrenic nerve palsy in the LM group.
Conclusions
Coronary air embolism was numerically less frequent in patients undergoing cryoballoon ablation with laryngeal mask ventilation than in those managed with ASV, although the difference did not reach statistical significance. Further prospective studies are warranted to clarify the potential role of respiratory management in procedural safety.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, Kanagawa, Japan.
- Department of Kitasato Clinical Research Center, Kitasato University School of Medicine, Kanagawa, Japan.
ORCID-Profile: Hidehira Fukaya, Gen Matsuura, Jun Oikawa, Wataru Shinkai, Megumi Traiwa, Sho Ogiso, Yusuke Murayama, Daiki Saito, Yuki Arakawa, Shuhei Kobayashi, Hironori Nakamura, Naruya Ishizue, Jun Kishihara, Junya Ako
Zitieren
APA
Fukaya, H., Matsuura, G., Oikawa, J., Shinkai, W., Traiwa, M., Ogiso, S., Murayama, Y., Saito, D., Arakawa, Y., Kobayashi, S., Nakamura, H., Ishizue, N., Kishihara, J., & Ako, J. (2026). Air Embolism During Cryoballoon Ablation for Atrial Fibrillation Under Different Respiratory Management Strategies. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70498
Vancouver
Fukaya H, Matsuura G, Oikawa J, Shinkai W, Traiwa M, Ogiso S, et al. Air Embolism During Cryoballoon Ablation for Atrial Fibrillation Under Different Respiratory Management Strategies. Pacing and Clinical Electrophysiology. 2026. doi:10.1111/pace.70498
BibTeX
@article{Fukaya2026,
author = {Fukaya, Hidehira and Matsuura, Gen and Oikawa, Jun and Shinkai, Wataru and Traiwa, Megumi and Ogiso, Sho and Murayama, Yusuke and Saito, Daiki and Arakawa, Yuki and Kobayashi, Shuhei and Nakamura, Hironori and Ishizue, Naruya and Kishihara, Jun and Ako, Junya},
title = {Air Embolism During Cryoballoon Ablation for Atrial Fibrillation Under Different Respiratory Management Strategies},
journal = {Pacing and Clinical Electrophysiology},
year = {2026},
doi = {10.1111/pace.70498}
}
EUVIMED