EUVIMEDEUVIMED entdecken
Crossref

Septal–Inferior Vena Cava Angle and Accurate Septal Implantation of Leadless Pacemakers: Computed Tomography‐Based Study

Takashi Okajima iD, Shinji Ishikawa, Yusuke Uemura iD, Yuta Ozaki iD, Shogo Yamaguchi iD, Takayuki Mitsuda, Kenji Takemoto, Yasuya Inden iD, Masato Watarai

Pacing and Clinical Electrophysiology · 06.08.2026

DOI: 10.1111/pace.70385 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pacing and Clinical Electrophysiology, online erschienen am 06.08.2026. Verfasst von Takashi Okajima und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Anjo Kosei Hospital, Anjo, Japan. Die Arbeit nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The Micra leadless pacemaker (LPM) should ideally be implanted in the septal location to enhance safety. However, the probability of accurate septal implantation and its predictive factors have not been fully elucidated.

Methods

Eighty‐three consecutive patients who underwent computed tomography (CT) following LPM implantation were included. The ventricular septum was targeted using a standard fluoroscopic‐guided transfemoral approach. The LPM implantation site was classified as septal or non‐septal based on CT findings. The septal–inferior vena cava (IVC) angle was evaluated as a patient‐specific anatomical parameter representing the relationship between IVC inflow and the ventricular septum.

Results

Accurate septal implantation was achieved in 44 patients (53.0%). The septal–IVC angle was significantly larger in the septal group than in the non‐septal group (13.1 ± 11.6° vs. 2.7 ± 10.6°, p < 0.001). Multivariate logistic regression analysis indicated that the septal–IVC angle (odds ratio, 1.09; 95% confidence interval, 1.03–1.14; p = 0.002) was independently associated with the incidence of septal implantation. The optimal cutoff value for the septal–IVC angle was 6°, with a sensitivity of 77.3% and a specificity of 66.7% for predicting septal implantation. There were no cases of cardiac tamponade or pericardial effusion. No significant differences in long‐term outcomes, including all‐cause mortality, cardiac mortality, and heart failure hospitalization, were observed between the two groups.

Conclusions

Accurate septal implantation was observed in 53.0% of patients who had undergone LPM implantation with the standard femoral approach. A larger septal–IVC angle was associated with accurate septal implantation.

Schlagwörter

Stichwörter der Autor:innen

computed tomographyimplant locationleadless pacemakeroutcomesright ventricular septum

Autor:innen und Institutionen

  • Department of Cardiology, Anjo Kosei Hospital, Anjo, Japan.
  • Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.

ORCID-Profile: Takashi Okajima, Yusuke Uemura, Yuta Ozaki, Shogo Yamaguchi, Yasuya Inden

Zitieren

APA

Okajima, T., Ishikawa, S., Uemura, Y., Ozaki, Y., Yamaguchi, S., Mitsuda, T., Takemoto, K., Inden, Y., & Watarai, M. (2026). Septal–Inferior Vena Cava Angle and Accurate Septal Implantation of Leadless Pacemakers: Computed Tomography‐Based Study. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70385

Vancouver

Okajima T, Ishikawa S, Uemura Y, Ozaki Y, Yamaguchi S, Mitsuda T, et al. Septal–Inferior Vena Cava Angle and Accurate Septal Implantation of Leadless Pacemakers: Computed Tomography‐Based Study. Pacing and Clinical Electrophysiology. 2026. doi:10.1111/pace.70385

BibTeX
@article{Okajima2026,
  author = {Okajima, Takashi and Ishikawa, Shinji and Uemura, Yusuke and Ozaki, Yuta and Yamaguchi, Shogo and Mitsuda, Takayuki and Takemoto, Kenji and Inden, Yasuya and Watarai, Masato},
  title = {Septal–Inferior Vena Cava Angle and Accurate Septal Implantation of Leadless Pacemakers: Computed Tomography‐Based Study},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2026},
  doi = {10.1111/pace.70385}
}
Kostenlos starten →