Ventricular Synchrony in Targeted Right Ventricular Septal Pacing: A Prospective Paired Comparison to Apical Placement
Pacing and Clinical Electrophysiology · 29.07.2026
DOI: 10.1111/pace.70383 ↗Kurz gefasst
Fachartikel in der Zeitschrift Pacing and Clinical Electrophysiology, online erschienen am 29.07.2026. Verfasst von Bianca Iulia Catrina und 5 weiteren Autor:innen. Beteiligte Einrichtung: County Clinical Emergency Hospital of Sibiu, Sibiu, Romania. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/Objectives Right ventricular (RV) apical pacing, the standard pacing approach, often induces ventricular dyssynchrony, potentially impairing cardiac function. This study aims to investigate whether targeted RV septal pacing, guided by functional electrophysiological feedback during implantation, reduces ventricular dyssynchrony compared to conventional apical pacing.
Methods
This prospective, observational study included 18 patients with standard pacing indications (second‐degree or intermittent third‐degree atrioventricular block, sinus node disease) undergoing dual chamber pacemaker implantation. Each patient initially underwent temporary transvenous RV apical pacing via femoral access, followed by permanent ventricular lead implantation using a functionally guided technique targeting the RV septum. Electrocardiographic (QRS duration) and echocardiographic parameters (septal–posterior wall delay—SPWD, interventricular mechanical delay—IVMD) were measured at baseline, during RV apical pacing, and during targeted septal pacing. Comparisons were performed using paired within‐subject statistical analysis. Lead parameters and follow‐up data were also collected after implantation.
Results
RV pacing significantly increased ventricular dyssynchrony parameters compared to baseline, regardless of lead position. Targeted RV septal pacing, however, resulted in significantly lower dyssynchrony than conventional RV apical pacing as quantified by QRS duration, SPWD and IVMD. No acute procedural complications were observed, and pacing lead parameters remained stable during follow‐up.
Conclusions
Targeted RV septal pacing, guided by electrophysiological criteria during implantation, was associated with significantly lower ventricular dyssynchrony than conventional apical pacing. These exploratory findings from an acute paired comparison suggest that functionally guided RV septal pacing may represent a practical alternative to conventional apical pacing and warrant confirmation in larger studies with long‐term clinical follow‐up.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- County Clinical Emergency Hospital of Sibiu, Sibiu, Romania.
- Pathophysiology Department, Faculty of Medicine, Lucian Blaga University of Sibiu, Sibiu, Romania.
- Cardiology Department, Faculty of Medicine, Lucian Blaga University of Sibiu, Sibiu, Romania.
- Clinical Surgical Department, Faculty of Medicine, Lucian Blaga University of Sibiu, Sibiu, Romania.
- Physiology Pathophysiology Department, Faculty of Medicine, Lucian Blaga University of Sibiu, Sibiu, Romania.
- Medical Clinic Number 1, 4th Department of Internal Medicine, Iuliu Hațieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania.
ORCID-Profile: Mihai Octavian Negrea, Florin-Leontin Lazar
Zitieren
APA
Catrina, B. I., Negrea, M. O., Tănăsescu, C., Batar, F., Lazar, F. L., & Manitiu, I. (2026). Ventricular Synchrony in Targeted Right Ventricular Septal Pacing: A Prospective Paired Comparison to Apical Placement. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70383
Vancouver
Catrina BI, Negrea MO, Tănăsescu C, Batar F, Lazar FL, Manitiu I. Ventricular Synchrony in Targeted Right Ventricular Septal Pacing: A Prospective Paired Comparison to Apical Placement. Pacing and Clinical Electrophysiology. 2026. doi:10.1111/pace.70383
BibTeX
@article{Catrina2026,
author = {Catrina, Bianca Iulia and Negrea, Mihai Octavian and Tănăsescu, Ciprian and Batar, Florina and Lazar, Florin-Leontin and Manitiu, Ioan},
title = {Ventricular Synchrony in Targeted Right Ventricular Septal Pacing: A Prospective Paired Comparison to Apical Placement},
journal = {Pacing and Clinical Electrophysiology},
year = {2026},
doi = {10.1111/pace.70383}
}
EUVIMED