Percutaneous Extraction of a Long‐Standing, Inadvertently Malpositioned Left‐Atrial Lead during CIED Infection
Pacing and Clinical Electrophysiology · 25.06.2026
DOI: 10.1111/pace.70336 ↗Kurz gefasst
Fallbericht in der Zeitschrift Pacing and Clinical Electrophysiology, online erschienen am 25.06.2026. Verfasst von Tianbao Yao und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China. Die Arbeit nennt 13 Literaturangaben.
Abstract (Originalsprache)
There is limited evidence in the literature regarding the safety and feasibility of transvenous extraction for leads malpositioned in the left heart for an extended period. This report presents a challenging case of a 44‐year‐old male with a pacemaker pocket infection and bacteremia, in whom a previously unrecognized atrial lead malposition into the left atrium—present for 17 years—was identified and successfully extracted. This report suggests that percutaneous extraction of a long‐standing, malpositioned lead in the left heart is both mandatory and feasible in the setting of cardiac implantable electronic device infection.
Autor:innen und Institutionen
- Division of Cardiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
ORCID-Profile: Peng Nie
Zitieren
APA
Yao, T., Nie, P., Wang, Z., & Mao, J. (2026). Percutaneous Extraction of a Long‐Standing, Inadvertently Malpositioned Left‐Atrial Lead during CIED Infection. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70336
Vancouver
Yao T, Nie P, Wang Z, Mao J. Percutaneous Extraction of a Long‐Standing, Inadvertently Malpositioned Left‐Atrial Lead during CIED Infection. Pacing and Clinical Electrophysiology. 2026. doi:10.1111/pace.70336