EUVIMEDEUVIMED entdecken
Crossref

Differential HFpEF Response After Catheter Ablation in Persistent AF Patients With Small Low Voltage Areas

Yasuyuki Egami iD, Taichi Mukai, Mikako Kise, Noriyuki Kobayashi, Ayako Sugino, Masaru Abe, Hiroaki Nohara, Shodai Kawanami, Koji Yasumoto, Naotaka Okamoto, Yasuharu Matsunaga-Lee iD, Masamichi Yano und 1 weitere

Pacing and Clinical Electrophysiology · 2026-11 · 49 (11) · 1843-1850

DOI: 10.1111/pace.70300 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pacing and Clinical Electrophysiology, online erschienen am 26.05.2026. Verfasst von Yasuyuki Egami und 12 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Osaka Rosai Hospital, Sakai, Osaka, Japan. Hauptthemen laut MEDLINE: Catheter Ablation, Atrial Fibrillation, Heart Failure, Stroke Volume. Die Arbeit nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Low voltage areas (LVAs) in the left atrium (LA) is associated with atrial fibrillation (AF) recurrence and heart failure with preserved ejection fraction (HFpEF). The clinical significance of small LVAs (< 5.0 cm 2 ) in patients with persistent atrial fibrillation (PerAF) remains unclear. This study evaluated the impact of catheter ablation (CA) on HFpEF status in PerAF patients with small LVAs.

Methods

We included 62 consecutive PerAF patients with total LA LVAs < 5.0 cm 2 undergoing initial CA between June 2019 and March 2023. Patients were divided by the median LVA into the sLVA‐Low (0.0–1.6 cm 2 ) and sLVA‐High (1.7–4.9 cm 2 ). HFA‐PEFF scores were assessed at baseline and 12 months. Changes in HFA‐PEFF scores (ΔHFA‐PEFF), arrhythmia recurrence, and adverse clinical events were compared.

Results

Baseline HFA‐PEFF scores were higher in sLVA‐High than in sLVA‐Low (4 [3–4] vs. 2 [2–3], p = 0.013). At 12 months, HFA‐PEFF scores remained elevated in sLVA‐High (3.5 [2–5] vs. 2 [2–4], p = 0.037), with a greater prevalence of HFA‐PEFF scores 5–6 (30% vs. 8%, p = 0.043). However, ΔHFA‐PEFF scores, AF recurrence rates, the incidence of adverse events did not differ significantly between the two groups.

Conclusion

Among PerAF patients with small LVAs (

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Catheter AblationAtrial FibrillationHeart FailureStroke VolumeHumansFemaleMaleAgedTreatment OutcomeRecurrenceHeart AtriaMiddle Aged

Stichwörter der Autor:innen

ablationheart failure with preserved ejection fractionpersistent atrial fibrillationsmall low voltage areas

Autor:innen und Institutionen

  • Division of Cardiology, Osaka Rosai Hospital, Sakai, Osaka, Japan.

ORCID-Profile: Yasuyuki Egami, Yasuharu Matsunaga-Lee, Masami Nishino

Zitieren

APA

Egami, Y., Mukai, T., Kise, M., Kobayashi, N., Sugino, A., Abe, M., Nohara, H., Kawanami, S., Yasumoto, K., Okamoto, N., Matsunaga-Lee, Y., Yano, M., & Nishino, M. (2026). Differential HFpEF Response After Catheter Ablation in Persistent AF Patients With Small Low Voltage Areas. Pacing and Clinical Electrophysiology, 49(11), 1843-1850. https://doi.org/10.1111/pace.70300

Vancouver

Egami Y, Mukai T, Kise M, Kobayashi N, Sugino A, Abe M, et al. Differential HFpEF Response After Catheter Ablation in Persistent AF Patients With Small Low Voltage Areas. Pacing and Clinical Electrophysiology. 2026;49(11):1843-1850. doi:10.1111/pace.70300

BibTeX
@article{Egami2026,
  author = {Egami, Yasuyuki and Mukai, Taichi and Kise, Mikako and Kobayashi, Noriyuki and Sugino, Ayako and Abe, Masaru and Nohara, Hiroaki and Kawanami, Shodai and Yasumoto, Koji and Okamoto, Naotaka and Matsunaga-Lee, Yasuharu and Yano, Masamichi and Nishino, Masami},
  title = {Differential HFpEF Response After Catheter Ablation in Persistent AF Patients With Small Low Voltage Areas},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2026},
  volume = {49},
  number = {11},
  pages = {1843--1850},
  doi = {10.1111/pace.70300}
}
Kostenlos starten →