Where to Perform the Pulmonary Vein Isolation in Third‐Ablation Paroxysmal AF?
Pacing and Clinical Electrophysiology · 2026-11 · 49 (11) · 1806-1811
DOI: 10.1111/pace.70288 ↗Kurz gefasst
Fallbericht in der Zeitschrift Pacing and Clinical Electrophysiology, online erschienen am 12.05.2026. Verfasst von Juan Xu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Shanghai General Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China. Hauptthemen laut MEDLINE: Pulmonary Veins, Atrial Fibrillation, Catheter Ablation. Die Arbeit nennt 8 Literaturangaben.
Abstract (Originalsprache)
Background
Pulmonary vein isolation (PVI) is the cornerstone of atrial fibrillation (AF) ablation, although the optimal site for ablation remains controversial. Methods and Results We reported a 52‐ year‐old woman with the third paroxysmal AF ablation. Mapping showed that the ostial PV , but not the PV antrum ,was isolated. During circumferential PV antrum ablation, the atrial arrhythmias were eliminated. The roof line and superior vena cava isolation was empirically performed. During the 84‐month follow‐up, she was free of arrhythmias without antiarrhythmics.
Conclusion
Isolation of the PV antrum, which was easily to be identify by image integration, should be checked and achieved for patients with AF recurrence after “successful and durable ostial PVI”. Clinical trial Registration Statement No clinical trial registration number is applicable.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Shanghai General Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China.
ORCID-Profile: Juan Xu, Tong Wei, Songwen Chen
Zitieren
APA
Xu, J., Wei, T., Liang, L., Lu, X., Li, J., Liu, S., & Chen, S. (2026). Where to Perform the Pulmonary Vein Isolation in Third‐Ablation Paroxysmal AF?. Pacing and Clinical Electrophysiology, 49(11), 1806-1811. https://doi.org/10.1111/pace.70288
Vancouver
Xu J, Wei T, Liang L, Lu X, Li J, Liu S, et al. Where to Perform the Pulmonary Vein Isolation in Third‐Ablation Paroxysmal AF?. Pacing and Clinical Electrophysiology. 2026;49(11):1806-1811. doi:10.1111/pace.70288
BibTeX
@article{Xu2026,
author = {Xu, Juan and Wei, Tong and Liang, Lin and Lu, Xiaofeng and Li, Jun and Liu, Shaowen and Chen, Songwen},
title = {Where to Perform the Pulmonary Vein Isolation in Third‐Ablation Paroxysmal AF?},
journal = {Pacing and Clinical Electrophysiology},
year = {2026},
volume = {49},
number = {11},
pages = {1806--1811},
doi = {10.1111/pace.70288}
}
EUVIMED