Metaanalyse in der Zeitschrift Pacing and Clinical Electrophysiology, online erschienen am 31.05.2026. Verfasst von Kartik Gupta und 8 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiac Electrophysiology, Department of Internal Medicine, Henry Ford Health, Detroit, Michigan, USA. Hauptthemen laut MEDLINE: Anti-Bacterial Agents, Anti-Infective Agents, Defibrillators, Implantable, Pacemaker, Artificial. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Clinical guidelines do not recommend the routine rinsing of cardiac implantable electronic devices (CIED) with antimicrobials before pocket closure(“antimicrobial pocket flush.”) However, despite current recommendations and a lack of evidence regarding the utility of this practice for reducing CIED infections, the antimicrobial pocket flush is still commonly employed. Clarifying the true value of this technique is important for supporting evidence‐based practice and avoiding unnecessary antimicrobial use. Therefore, we performed meta‐analysis of observational studies to determine the effectiveness of this practice in preventing CIED infections.

Methods

We performed a systematic literature search for observational human studies investigating the effectiveness of employing the antimicrobial pocket flush to prevent CIED infection. A random effects meta‐analysis was performed. Effectiveness was estimated with the study‐level definitions of CIED infection. We performed subgroup analysis by type of antimicrobial‐antiseptic or antibiotic.

Results

A total of seven studies including 12,283 patients were analyzed. Over half of the CIED implantation procedures (61.5%) included the antimicrobial pocket flush, and between 8.4% and 85% of the implantations were revision procedures. Studies used various antimicrobials for pocket flush, and definitions of CIED infection varied. Overall infection rates ranged from 0.5%–1.5%. CIED infection rates did not differ significantly between procedures performed with versus without antimicrobial pocket flush (0.8% vs. 1.1%; relative risk 0.80; 95% confidence interval 0.39–1.63; p = 0.54). There was no difference in the subgroup analysis by antiseptic or antibiotic use.

Conclusion

Our results suggest that the antimicrobial pocket flush provides no benefit in preventing CIED infection, reinforcing the current guidelines that do not support its routine use.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Anti-Bacterial AgentsAnti-Infective AgentsDefibrillators, ImplantablePacemaker, ArtificialProsthesis-Related InfectionsHumansRisk FactorsTreatment Outcome

Substanzen

Anti-Bacterial AgentsAnti-Infective Agents

Autor:innen und Institutionen

  • Division of Cardiac Electrophysiology, Department of Internal Medicine, Henry Ford Health, Detroit, Michigan, USA.
  • Division of Cardiology, University of Vermont Medical Centre, Burlington, Vermont, USA.
  • Division of Hospital Medicine, Department of Medicine, Henry Ford Health, Detroit, Michigan, USA.
  • Department of Cardiovascular Medicine, The University of Kansas Medical Center, Kansas City, Kansas, USA.
  • Department of Internal Medicine, Michigan State University School of Medicine, Detroit, Michigan, USA.
  • Department of Internal Medicine, Wayne State University School of Medicine, Detroit, Michigan, USA.

ORCID-Profile: Bharat Rawlley, Mohamad Raad

Zitieren

APA

Gupta, K., Rawlley, B., Kakar, T. S., Noheria, A., Greenberg, J., Ilg, K., Maskoun, W., Khan, A., & Raad, M. (2026). Antimicrobial Pocket Flush and Cardiac Implantable Electronic Device Infection: Meta‐Analysis of Real‐World Studies. Pacing and Clinical Electrophysiology, 49(9), 1294-1300. https://doi.org/10.1111/pace.70264

Vancouver

Gupta K, Rawlley B, Kakar TS, Noheria A, Greenberg J, Ilg K, et al. Antimicrobial Pocket Flush and Cardiac Implantable Electronic Device Infection: Meta‐Analysis of Real‐World Studies. Pacing and Clinical Electrophysiology. 2026;49(9):1294-1300. doi:10.1111/pace.70264

BibTeX
@article{Gupta2026,
  author = {Gupta, Kartik and Rawlley, Bharat and Kakar, Tanya Singh and Noheria, Amit and Greenberg, Joshua and Ilg, Karl and Maskoun, Waddah and Khan, Arfaat and Raad, Mohamad},
  title = {Antimicrobial Pocket Flush and Cardiac Implantable Electronic Device Infection: Meta‐Analysis of Real‐World Studies},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2026},
  volume = {49},
  number = {9},
  pages = {1294--1300},
  doi = {10.1111/pace.70264}
}
Kostenlos starten →