Breaking Frontiers—Leadless Atrial‐Ventricular Hybrid Upgrade to Dual Chamber Leadless Pacemaker
Pacing and Clinical Electrophysiology · 2026-10 · 49 (10) · 1567-1572
DOI: 10.1111/pace.70252 ↗Kurz gefasst
Fallbericht in der Zeitschrift Pacing and Clinical Electrophysiology, online erschienen am 13.04.2026. Verfasst von João Mendes Cravo und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, ULS Santa Maria, Faculdade de Medicina, CAML, CCUL@RISE, Universidade de Lisboa, Lisboa, Portugal. Hauptthemen laut MEDLINE: Pacemaker, Artificial, Atrioventricular Block, Sick Sinus Syndrome. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 21 Literaturangaben.
Abstract (Originalsprache)
Introduction
Leadless pacemakers (LP) have significantly reduced device‐related complications compared with conventional systems, yet limitations in atrial pacing and atrioventricular (AV) synchrony restrict their widespread use. Methods and Results We report an 87‐year‐old man with a history of stage 5 CKD on haemodialysis with complete AV block and a previously implanted Micra‐AV who developed symptomatic sinus node dysfunction. To restore AV synchrony and avoid transvenous implantation, an Abbott AVEIR AR atrial LP was implanted, achieving functional dual‐chamber leadless pacing. The procedure had no complications, and the follow‐up demonstrated 89% AV synchrony with symptomatic improvement.
Conclusion
This case demonstrates the feasibility of achieving a hybrid dual‐chamber leadless pacing system from two different manufacturers in selected patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, ULS Santa Maria, Faculdade de Medicina, CAML, CCUL@RISE, Universidade de Lisboa, Lisboa, Portugal.
- Department of Cardiology, ULS Santa Maria, Faculdade de Medicina, Universidade de Lisboa, Lisboa, Portugal.
- Unidade Local de Saúde (ULS) Litoral Alentejano, Santiago do Cacém, Portugal.
Zitieren
APA
Cravo, J. M., Ferreira, D. R., Bernardes, A. A., Coelho, L., Machado, E. M., Pinto, F. J., de Sousa, J., & Marques, P. N. C. (2026). Breaking Frontiers—Leadless Atrial‐Ventricular Hybrid Upgrade to Dual Chamber Leadless Pacemaker. Pacing and Clinical Electrophysiology, 49(10), 1567-1572. https://doi.org/10.1111/pace.70252
Vancouver
Cravo JM, Ferreira DR, Bernardes AA, Coelho L, Machado EM, Pinto FJ, et al. Breaking Frontiers—Leadless Atrial‐Ventricular Hybrid Upgrade to Dual Chamber Leadless Pacemaker. Pacing and Clinical Electrophysiology. 2026;49(10):1567-1572. doi:10.1111/pace.70252
BibTeX
@article{Cravo2026,
author = {Cravo, João Mendes and Ferreira, Diogo Rosa and Bernardes, Ana Abreu and Coelho, Lénia and Machado, Emiliano Manuel and Pinto, Fausto J and de Sousa, João and Marques, Pedro N C},
title = {Breaking Frontiers—Leadless Atrial‐Ventricular Hybrid Upgrade to Dual Chamber Leadless Pacemaker},
journal = {Pacing and Clinical Electrophysiology},
year = {2026},
volume = {49},
number = {10},
pages = {1567--1572},
doi = {10.1111/pace.70252}
}
EUVIMED