EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Algorithm Improvements in an Insertable Cardiac Monitor Reduce False Positives and Episode Review Burden

Mark Richards, Molly Kupfer iD, Keith Herrmann, Deepa Mahajan, David Perschbacher, Abhijit Rajan, Vasanth Ravikumar, Martin Burke

Pacing and Clinical Electrophysiology · 2025-12 · 48 (12) · 1337-1343

DOI: 10.1111/pace.70043 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pacing and Clinical Electrophysiology, online erschienen am 10.11.2025. Verfasst von Mark Richards und 7 weiteren Autor:innen. Beteiligte Einrichtung: Baylor Scott & White Arrhythmia Management, Plano, Texas, USA. Hauptthemen laut MEDLINE: Algorithms, Electrocardiography, Ambulatory, Atrial Fibrillation, Bradycardia. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: by Boston Scientific Corporation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The use of insertable cardiac monitors (ICM) for arrhythmia monitoring continues to grow steadily. However, ICM performance remains less than perfect, and the volume of transmitted data poses a challenge to clinics. Here, we evaluate the impact of three improvements implemented in the LUX‐Dx II+ ICM for atrial fibrillation (AF), pause, and bradycardia detection.

Methods

Enhanced AF and pause algorithms were evaluated using real‐world ECG data and compared against the predecessor LUX‐Dx algorithms. Optimized nighttime (11 p.m.–7 a.m.) programming settings were simulated on LUX‐Dx data to evaluate the reduction of non‐actionable nocturnal bradycardia (>30 bpm) and pause (98% sensitivity relative to the legacy algorithm. False positive reduction and relative sensitivity were even higher (74% and 100%, respectively) in a subset of patients with more sensitive AF programming settings. The enhanced pause algorithm reduced false positives by 62.5% in the training set and 48.6% in the test set, while maintaining 100% relative sensitivity. Application of adjusted nocturnal detection thresholds reduced the number of nighttime bradycardia and pause episodes by 98% and 90%, corresponding to an overall episode reduction of 75% and 56%, respectively.

Conclusion

The enhanced ICM algorithms and programming settings substantially reduced false positive AF and pause detections as well as non‐actionable nighttime bradycardia and pause detections. These enhancements are expected to improve ICM performance and workflow in the device clinic.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AlgorithmsElectrocardiography, AmbulatoryAtrial FibrillationBradycardiaHumansFalse Positive ReactionsMaleFemale

Stichwörter der Autor:innen

arrhythmiaatrial fibrillationbradycardiainsertable cardiac monitorpause

Autor:innen und Institutionen

  • Baylor Scott & White Arrhythmia Management, Plano, Texas, USA.
  • Boston Scientific Corporation, St. Paul, Minnesota, USA.
  • CorVita Science Foundation, Chicago, Illinois, USA.

ORCID-Profile: Molly Kupfer

Förderung

  • by Boston Scientific Corporation

Zitieren

APA

Richards, M., Kupfer, M., Herrmann, K., Mahajan, D., Perschbacher, D., Rajan, A., Ravikumar, V., & Burke, M. (2025). Algorithm Improvements in an Insertable Cardiac Monitor Reduce False Positives and Episode Review Burden. Pacing and Clinical Electrophysiology, 48(12), 1337-1343. https://doi.org/10.1111/pace.70043

Vancouver

Richards M, Kupfer M, Herrmann K, Mahajan D, Perschbacher D, Rajan A, et al. Algorithm Improvements in an Insertable Cardiac Monitor Reduce False Positives and Episode Review Burden. Pacing and Clinical Electrophysiology. 2025;48(12):1337-1343. doi:10.1111/pace.70043

BibTeX
@article{Richards2025,
  author = {Richards, Mark and Kupfer, Molly and Herrmann, Keith and Mahajan, Deepa and Perschbacher, David and Rajan, Abhijit and Ravikumar, Vasanth and Burke, Martin},
  title = {Algorithm Improvements in an Insertable Cardiac Monitor Reduce False Positives and Episode Review Burden},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2025},
  volume = {48},
  number = {12},
  pages = {1337--1343},
  doi = {10.1111/pace.70043}
}
Kostenlos starten →