Lead Performance and Echocardiographic Outcomes for Delayed Bundle Capture Loss During Conduction System Pacing
Pacing and Clinical Electrophysiology · 2025
DOI: 10.1111/pace.15178 ↗Kurz gefasst
Fachartikel in der Zeitschrift Pacing and Clinical Electrophysiology, 2025. Verfasst von Shengjie Wu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, the First Affiliated Hospital of Wenzhou Medical University, Wenzhou, China. Hauptthemen laut MEDLINE: Bundle-Branch Block, Echocardiography, Electrodes, Implanted, Cardiac Pacing, Artificial. Die Arbeit nennt 14 Literaturangaben. Gefördert von: Basic Science Research Fund of Wenzhou, Medical Health Science and Technology Project of Zhejiang Provincial Health Commission.
Abstract (Originalsprache)
Background
Conduction system pacing (CSP) is increasingly recognized for mitigating the adverse hemodynamic effects commonly associated with conventional ventricular pacing. However, there is limited data on the lead performance and echocardiographic outcomes for delayed bundle capture loss during CSP.
Objective
To evaluate the rate of complete loss of bundle capture/correction during CSP and assess the subsequent clinical outcomes.
Method
Patients who underwent successful CSP lead implantation with indications for ventricular pacing or cardiac resynchronization therapy (CRT) were screened. The reasons for complete loss of capture or failed LBBB correction were identified, and subsequent clinical outcomes were analyzed.
Result
Out of 2636 patients screened, nine experienced complete loss of bundle capture or LBBB correction during follow‐up. Loss of capture was attributed to unexplained causes ( n = 6), near‐complete electrode dislodgement ( n = 1), surgical damage ( n = 1), and electrode malfunction ( n = 1). The six patients with CRT indication and declining cardiac function underwent lead revision, with left ventricular ejection fraction (LVEF) improving from 40.6 ± 17.3% to 59.1 ± 6.0% at the last follow‐up with the bundle capture threshold of 0.63 ± 0.14 V/0.5 ms. The remaining 3 atrioventricular block patients with stable cardiac function did not undergo lead revision and the local myocardium threshold of 0.58± 0.31 V/0.5 ms.
Conclusion
The incidence of complete capture loss during CSP is low recapturing/recorrecting the bundle significantly improves cardiac function in patients with CRT indications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, the First Affiliated Hospital of Wenzhou Medical University, Wenzhou, China.
ORCID-Profile: Weijian Huang
Förderung
- Basic Science Research Fund of Wenzhou
- Medical Health Science and Technology Project of Zhejiang Provincial Health Commission
Zitieren
APA
Wu, S., Su, L., Fang, Y., Shang, W., Wang, X., Wang, J., Xu, L., Wang, S., & Huang, W. (2025). Lead Performance and Echocardiographic Outcomes for Delayed Bundle Capture Loss During Conduction System Pacing. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.15178
Vancouver
Wu S, Su L, Fang Y, Shang W, Wang X, Wang J, et al. Lead Performance and Echocardiographic Outcomes for Delayed Bundle Capture Loss During Conduction System Pacing. Pacing and Clinical Electrophysiology. 2025. doi:10.1111/pace.15178
BibTeX
@article{Wu2025,
author = {Wu, Shengjie and Su, Lan and Fang, Yuchao and Shang, Wenxuan and Wang, Xinxin and Wang, Junwei and Xu, Lei and Wang, Songjie and Huang, Weijian},
title = {Lead Performance and Echocardiographic Outcomes for Delayed Bundle Capture Loss During Conduction System Pacing},
journal = {Pacing and Clinical Electrophysiology},
year = {2025},
doi = {10.1111/pace.15178}
}
EUVIMED