EUVIMEDEUVIMED entdecken
Crossref

Can phrenic nerve injury be anticipated by larger cryoballoons?

Kentaro Goto iD, Shinsuke Miyazaki, Takuro Nishimura iD, Tomomasa Takamiya, Susumu Tao, Masateru Takigawa, Tetsuo Sasano

Pacing and Clinical Electrophysiology · 2024

DOI: 10.1111/pace.14859 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pacing and Clinical Electrophysiology, 2024. Verfasst von Kentaro Goto und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan. Hauptthemen laut MEDLINE: Atrial Fibrillation, Cryosurgery, Peripheral Nerve Injuries, Pulmonary Veins. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 7 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Recently, a novel size‐adjustable cryoballoon has been introduced in clinical practice, which can be inflated to two different diameters (28 and 31 mm). The 31 mm cryoballoon is specifically designed to achieve better contact with remodeled pulmonary veins (PVs) that have wider ostia while avoiding deep cannulation, thereby potentially reducing the risk of phrenic nerve injury (PNI) associated with deep balloon cannulation. However, we encountered two cases of PNI during cryoballoon ablation using the novel system among our initial 25 consecutive case series. Herein, we present two cases that exhibited PNI during freezing of the right superior PV with a size‐adjustable balloon. While larger balloons are expected to create a larger area of isolation, the safety of this novel balloon system needs to be evaluated in a large‐scale clinical study.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationCryosurgeryPeripheral Nerve InjuriesPulmonary VeinsCatheter AblationHumansPhrenic NerveTreatment Outcome

Stichwörter der Autor:innen

atrial fibrillationphrenic nerve injurysize-adjustable cryoballoon

Autor:innen und Institutionen

  • Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan.

ORCID-Profile: Kentaro Goto, Takuro Nishimura

Zitieren

APA

Goto, K., Miyazaki, S., Nishimura, T., Takamiya, T., Tao, S., Takigawa, M., & Sasano, T. (2024). Can phrenic nerve injury be anticipated by larger cryoballoons?. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.14859

Vancouver

Goto K, Miyazaki S, Nishimura T, Takamiya T, Tao S, Takigawa M, et al. Can phrenic nerve injury be anticipated by larger cryoballoons?. Pacing and Clinical Electrophysiology. 2024. doi:10.1111/pace.14859

BibTeX
@article{Goto2024,
  author = {Goto, Kentaro and Miyazaki, Shinsuke and Nishimura, Takuro and Takamiya, Tomomasa and Tao, Susumu and Takigawa, Masateru and Sasano, Tetsuo},
  title = {Can phrenic nerve injury be anticipated by larger cryoballoons?},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2024},
  doi = {10.1111/pace.14859}
}
Kostenlos starten →