Pulmonary vein isolation by means of a novel cryoballoon technology in paroxysmal atrial fibrillation patients: 1‐year outcome from a large Italian multicenter clinical registry

Stefano Bianchi, Antonio De Simone, Saverio Iacopino iD, Gaetano Fassini, Maurizio Malacrida iD, Pietro Rossi, Giuseppe Stabile iD, Andrea Petretta, Fabrizio Tundo, Filippo Maria Cauti iD, Sara Iuliano, Pasquale Filannino und 6 weitere

Pacing and Clinical Electrophysiology · 2023-11 · 46 (11) · 1302-1309

DOI: 10.1111/pace.14839 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Pacing and Clinical Electrophysiology, online erschienen am 17.10.2023. Verfasst von Stefano Bianchi und 17 weiteren Autor:innen. Beteiligte Einrichtung: Arrhythmology Unit, San Giovanni Calibita Hospital, Fatebefratelli, Rome, Italy. Hauptthemen laut MEDLINE: Atrial Fibrillation, Pulmonary Veins, Cryosurgery, Catheter Ablation. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Recently, a new cryoballoon (CB) technology (POLARx; Boston Scientific) has come onto the market. Preliminary data have shown that its acute safety and efficacy are similar to those of the first‐generation CB. The aim of this study was to assess the medium‐term outcome of pulmonary vein isolation (PVI) with the POLARxTM CB in a large multicenter registry.

Methods

We prospectively collected data on 125 consecutive patients with paroxysmal atrial fibrillation (AF) who underwent PVI by means of a novel CB system. Two cases of transient phrenic nerve palsy occurred, with full recovery in the 48h post procedure; no major procedure‐related adverse events were reported. During the 90‐day blanking period, 4 (3.2%) patients experienced an early recurrence. After the blanking period, over a mean follow‐up of 411 ± 62 days, 19 patients (15.2%) suffered an AF/atrial tachycardia (AT) recurrence. The 1‐year freedom from AF/AT recurrence was 86.4% ( n = 17): 10 (8%) patients had an AF recurrence, 6 (4.8%) had an AT occurrence and 1 (0.8%) suffered both events. Patients with AF/AT recurrences had both a shorter deflation time and total deflation time. Moreover, CB ablations with measured TTI < 90 s and TTI < 60 s were more frequent in patients without AF/AT recurrence (88.5% and 77.4%, respectively) than in those who experienced at least one AF/AT recurrence (67.5% and 55.0%, p = .001 and p = .005, respectively).

Conclusion

The novel POLARx cryo‐balloon system is safe and effective for PV isolation, displaying a 1‐year freedom from atrial arrhythmia recurrence of 86.4%, which is in line to that reported with AFA‐Pro CB or RF ablation. Clinical trial registration Catheter Ablation of Arrhythmias with a High‐Density Mapping System in Real‐World Practice (CHARISMA). URL: http://clinicaltrials.gov/ Identifier: NCT03793998. Registration date: January 4, 2019.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationPulmonary VeinsCryosurgeryCatheter AblationHumansTreatment OutcomeItalyRegistriesRecurrence

Stichwörter der Autor:innen

AF recurrencePOLARxPVIatrial fibrillationcryoballoon ablationoutcome

Autor:innen und Institutionen

  • Arrhythmology Unit, San Giovanni Calibita Hospital, Fatebefratelli, Rome, Italy.
  • Laboratorio di Elettrofisiologia, Clinica San Michele, Maddaloni, Caserta, Italy.
  • Maria Cecilia Hospital, Ravenna, Cotignola, Italy.
  • Department of Clinical Electrophysiology & Cardiac Pacing, Centro Cardiologico Monzino, IRCCS, Milan, Italy.
  • Boston Scientific, Milan, Italy.
  • Mediterranea Cardiocentro, Napoli, Italy.

ORCID-Profile: Saverio Iacopino, Maurizio Malacrida, Giuseppe Stabile, Filippo Maria Cauti

Zitieren

APA

Bianchi, S., De Simone, A., Iacopino, S., Fassini, G., Malacrida, M., Rossi, P., Stabile, G., Petretta, A., Tundo, F., Cauti, F. M., Iuliano, S., Filannino, P., Moltrasio, M., Morlacchi Bonfanti, M., Pelargonio, G., Pecora, D., Ferraro, A., & Tondo, C. (2023). Pulmonary vein isolation by means of a novel cryoballoon technology in paroxysmal atrial fibrillation patients: 1‐year outcome from a large Italian multicenter clinical registry. Pacing and Clinical Electrophysiology, 46(11), 1302-1309. https://doi.org/10.1111/pace.14839

Vancouver

Bianchi S, De Simone A, Iacopino S, Fassini G, Malacrida M, Rossi P, et al. Pulmonary vein isolation by means of a novel cryoballoon technology in paroxysmal atrial fibrillation patients: 1‐year outcome from a large Italian multicenter clinical registry. Pacing and Clinical Electrophysiology. 2023;46(11):1302-1309. doi:10.1111/pace.14839

BibTeX
@article{Bianchi2023,
  author = {Bianchi, Stefano and De Simone, Antonio and Iacopino, Saverio and Fassini, Gaetano and Malacrida, Maurizio and Rossi, Pietro and Stabile, Giuseppe and Petretta, Andrea and Tundo, Fabrizio and Cauti, Filippo Maria and Iuliano, Sara and Filannino, Pasquale and Moltrasio, Massimo and Morlacchi Bonfanti, Michela and Pelargonio, Gemma and Pecora, Domenico and Ferraro, Anna and Tondo, Claudio},
  title = {Pulmonary vein isolation by means of a novel cryoballoon technology in paroxysmal atrial fibrillation patients: 1‐year outcome from a large Italian multicenter clinical registry},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2023},
  volume = {46},
  number = {11},
  pages = {1302--1309},
  doi = {10.1111/pace.14839}
}
Kostenlos starten →