EUVIMEDEUVIMED entdecken
Crossref

Differences in the feasibility, anatomical parameters predicting procedural difficulty, and isolation area of a left atrial posterior wall isolation using radiofrequency versus cryoballoon catheters

Satoshi Sakai iD, Akihiro Takitsume, Tsunenari Soeda, Hiroyuki Kawata, Taku Nishida, Makoto Watanabe

Pacing and Clinical Electrophysiology · 2023

DOI: 10.1111/pace.14821 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pacing and Clinical Electrophysiology, 2023. Verfasst von Satoshi Sakai und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Nara Prefecture General Medical Center, Nara, Japan. Hauptthemen laut MEDLINE: Atrial Fibrillation, Cryosurgery, Catheter Ablation, Pulmonary Veins. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Backgrounds The difficulty and outcome of the adjunctive left atrial posterior wall isolation (LAPWI) in patients with persistent atrial fibrillation (PersAF) may be affected by the ablation energy used. This study aimed to compare the completion rate, anatomical parameters predicting procedural difficulty, and the isolation area of a LAPWI between the use of radiofrequency (RFA) and cryoballoon ablation (CBA).

Methods

We enrolled 95 and 93 patients with PersAF who underwent pulmonary vein isolation (PVI)+LAPWI using RFA (RF group) and CBA (CB group), respectively. Preoperative computed tomography was used to evaluate the anatomical features associated with an incomplete LAPWI. Post‐ablation 3‐dimensional maps were analyzed to quantify the isolation area.

Results

The completion rate of the LAPWI was significantly higher in the RF group than the CB group without touch‐up RFA (88.4% vs. 72.0%; p = .005). Predictors of incomplete LAPWI were a longer left inferior pulmonary vein (LIPV)‐esophageal distance ( p < .001) for RFA and a steeper angle of the LAPW ( p < .001) and longer transverse LAPW diameter ( p = .016) for CBA. The isolated non‐PV area with RFA or CBA alone was significantly greater in the CB group than the RF group (27.5 ± 9.5 cm 2 vs. 22.9 ± 6.9 cm 2 ; p < .001).

Conclusion

The position of the esophagus at a distance from the LIPV was associated with an incomplete LAPWI using RFA, while a steeper angle of the LAPW and transverse enlargement of the LAPW were associated with that using CBA. The completion rate of the LAPWI was higher with RFA, but the isolation area outside of the PVs was greater with CBA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationCryosurgeryCatheter AblationPulmonary VeinsHumansFeasibility StudiesHeart AtriaTreatment OutcomeRecurrence

Stichwörter der Autor:innen

atrial fibrillationcatheter ablationcryoballoon ablationleft atrial posterior wall isolationradiofrequency ablation

Autor:innen und Institutionen

  • Department of Cardiology, Nara Prefecture General Medical Center, Nara, Japan.
  • Department of Cardiovascular Medicine, Nara Medical University, Nara, Japan.

ORCID-Profile: Satoshi Sakai

Zitieren

APA

Sakai, S., Takitsume, A., Soeda, T., Kawata, H., Nishida, T., & Watanabe, M. (2023). Differences in the feasibility, anatomical parameters predicting procedural difficulty, and isolation area of a left atrial posterior wall isolation using radiofrequency versus cryoballoon catheters. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.14821

Vancouver

Sakai S, Takitsume A, Soeda T, Kawata H, Nishida T, Watanabe M. Differences in the feasibility, anatomical parameters predicting procedural difficulty, and isolation area of a left atrial posterior wall isolation using radiofrequency versus cryoballoon catheters. Pacing and Clinical Electrophysiology. 2023. doi:10.1111/pace.14821

BibTeX
@article{Sakai2023,
  author = {Sakai, Satoshi and Takitsume, Akihiro and Soeda, Tsunenari and Kawata, Hiroyuki and Nishida, Taku and Watanabe, Makoto},
  title = {Differences in the feasibility, anatomical parameters predicting procedural difficulty, and isolation area of a left atrial posterior wall isolation using radiofrequency versus cryoballoon catheters},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2023},
  doi = {10.1111/pace.14821}
}
Kostenlos starten →