EUVIMEDEUVIMED entdecken
Multizentrische Studie

Clinical outcomes of subcutaneous implantable cardiac defibrillator implantation – Iran SICD registry

Mahdiye Mehdinejadshani iD, Hamidreza Fallah, Farzad Kamali, Abolfath Alizadeh-Diz, Masoud Eslami, Allahyar Golabchi, Mehdi Taherpour, Javad Shahabi, Reza Mollazadeh, Shabnam Madadi, Amir Azhari, Abdolhossein Sodagar und 20 weitere

Pacing and Clinical Electrophysiology · 2023

DOI: 10.1111/pace.14668 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Pacing and Clinical Electrophysiology, 2023. Verfasst von Mahdiye Mehdinejadshani und 31 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac Electrophysiology, Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran. Hauptthemen laut MEDLINE: Defibrillators, Implantable. Die Arbeit nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The subcutaneous implantable‐defibrillator (S‐ICD) is a relatively new alternative to the transvenous ICD system to minimize intravascular lead‐related complications. This paper presents outcome of SICD implantation in patients enrolled in Iran S‐ICD registry.

Methods

Between October 2015 and June 2022, this prospective multicenter national registry included 223 patients with a standard indication for an ICD, who neither required bradycardia pacing nor needed cardiac resynchronization to evaluate the early post‐implant complications and long‐term follow‐up results of the S‐ICD system.

Results

The mean age of the patients was 45 ± 17 years. The majority (79.4%) were male. Ischemic cardiomyopathy (39.5%) was the most common underlying disorder among patients selected for S‐ICD implant. Most study patients (68.6%) had ICD for primary prevention of sudden cardiac death. Seven patients (3.1%) were found to have suboptimal lead positions. Six patients (2.7%) developed a pocket hematoma; all were managed medically. During a mean follow‐up of 2 years, the appropriate therapy was recorded in 13% of the patients and inappropriate ICD intervention mainly due to supraventricular tachycardia in 8.9%. Pocket infection was observed in four patients (1.8%) and five patients (2.2%) died mainly due to heart failure.

Conclusion

S‐ICDs were effective at detecting and treating both induced and spontaneous ventricular arrhythmias. Major clinical complications were rare.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Defibrillators, ImplantableHumansMaleFemaleAdultMiddle AgedProspective StudiesIranTreatment OutcomeDeath, Sudden, CardiacRegistries

Stichwörter der Autor:innen

appropriate therapyearly complicationsinappropriate therapylate outcomesubcutaneous implantable cardiac defibrillator

Autor:innen und Institutionen

  • Department of Cardiac Electrophysiology, Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran.
  • Department of Cardiology, Faculty of Medicine, Ayatollah Mousavi Hospital, Zanjan University of Medical Sciences, Zanjan, Iran.
  • Cardiac Electrophysiology Research Center, Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran.
  • Department of Cardiology, School of Medicine, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran.
  • The Advocate Center for Clinical Research, Ayatollah Yasrebi Hospital, Kashan, Iran.
  • Cardiology Department, Razavi Hospital, Mashhad, Iran.

ORCID-Profile: Mahdiye Mehdinejadshani, Majid Haghjoo

Zitieren

APA

Mehdinejadshani, M., Fallah, H., Kamali, F., Alizadeh-Diz, A., Eslami, M., Golabchi, A., Taherpour, M., Shahabi, J., Mollazadeh, R., Madadi, S., Azhari, A., Sodagar, A., Eftekharzadeh, M., Oraii, S., Fazelifar, A., Kazemisaeed, A., Ghorbanisharif, A., Dalili, M., Khorgami, M., …, & Haghjoo, M. (2023). Clinical outcomes of subcutaneous implantable cardiac defibrillator implantation – Iran SICD registry. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.14668

Vancouver

Mehdinejadshani M, Fallah H, Kamali F, Alizadeh-Diz A, Eslami M, Golabchi A, et al. Clinical outcomes of subcutaneous implantable cardiac defibrillator implantation – Iran SICD registry. Pacing and Clinical Electrophysiology. 2023. doi:10.1111/pace.14668

BibTeX
@article{Mehdinejadshani2023,
  author = {Mehdinejadshani, Mahdiye and Fallah, Hamidreza and Kamali, Farzad and Alizadeh-Diz, Abolfath and Eslami, Masoud and Golabchi, Allahyar and Taherpour, Mehdi and Shahabi, Javad and Mollazadeh, Reza and Madadi, Shabnam and Azhari, Amir and Sodagar, Abdolhossein and Eftekharzadeh, Mahmoud and Oraii, Saeed and Fazelifar, Amirfarjam and Kazemisaeed, Ali and Ghorbanisharif, Alireza and Dalili, Mohammad and Khorgami, Mohammadrafie and Heidari-Bakavoli, Alireaza and Jorat, Mohammadvahid and Nikoo, Hossein and Kheirkhah, Jalal and Saravi, Mehrdad and Khodaparast, Morteza and Mirzaali, Mansour and Emkanjoo, Zahra and Mirmasoumi, Mehrdad and Sadeghian, Saeed and Mokhtari, Meisam and Hedayati-Goudarzi, Mohammadtaghi and Haghjoo, Majid},
  title = {Clinical outcomes of subcutaneous implantable cardiac defibrillator implantation – Iran SICD registry},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2023},
  doi = {10.1111/pace.14668}
}
Kostenlos starten →