EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effect of Keeping Caspar Retractor During Prestige LP Cervical Disc Implantation on Intra‐ and Postoperative Outcomes

Xiaoqiang Zhao iD, Xiao Yang iD, Minghe Yao, Kangkang Huang, Tingkui Wu, Shihao Chen iD, Yi Deng, Hao Liu iD, Beiyu Wang iD

Orthopaedic Surgery · 2026-11 · 18 (11) · 2428-2439

DOI: 10.1111/os.70438 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Orthopaedic Surgery, online erschienen am 24.09.2026. Verfasst von Xiaoqiang Zhao und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan, China. Hauptthemen laut MEDLINE: Cervical Vertebrae, Total Disc Replacement, Intervertebral Disc Degeneration, Surgical Instruments. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: 1·3·5 project for disciplines of excellence, West China Hospital, Sichuan University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Implantation of the Prestige LP prosthesis requires substantial endplate modification and insertion forces, yet the manufacturer's guide recommends relaxing or completely removing the Caspar retractor before implantation, which we observed to cause vertebral instability during endplate preparation and prosthesis insertion. This study aimed to evaluate the effect of retaining the Caspar retractor during Prestige LP cervical disc implantation.

Methods

A total of 55 patients who underwent cervical disc arthroplasty (CDA) between January and December 2025 were retrospectively reviewed. The retractor group maintained the retractor during endplate preparation and prosthesis implantation, while the no‐retractor group removed it after discectomy. Clinical outcomes and radiographic parameters were assessed preoperatively, intraoperatively, and at 1 week, 3 months, and 6 months postoperatively. Statistical analyses were performed using two‐way repeated‐measures ANOVA, paired and independent t ‐tests, Mann–Whitney U test, and Chi‐square test.

Results

Clinical outcomes were similar in both groups. The retractor group demonstrated superior intraoperative stability with reduced functional spinal unit (FSU) Cobb angle fluctuations ( p = 0.001), fewer fluoroscopy exposures ( p = 0.044), and shorter prosthesis implantation times ( p = 0.017). The retractor group received significantly larger prostheses ( p < 0.001). Postoperatively, the retractor group exhibited greater FSU height, disc height, and larger interfacet distance (all p < 0.005) but these differences diminished by 6 months. The retractor group also showed smaller bone–implant interface gap ( p = 0.003) at 1 week, and more segmental range of motion ( p < 0.008) and FSU height loss ( p = 0.002) at 6 months. Subsidence and heterotopic ossification rates were comparable between groups.

Conclusion

During Prestige LP implantation in CDA, retaining the Caspar retractor enhanced intraoperative stability, improved prosthesis placement accuracy, and reduced fluoroscopy use, achieving comparable clinical outcomes. While associated with greater FSU height loss at 6 months, it did not increase complications, supporting its viability as a standard technical modification for Prestige LP implantation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cervical VertebraeTotal Disc ReplacementIntervertebral Disc DegenerationSurgical InstrumentsHumansFemaleMaleRetrospective StudiesAdultMiddle AgedTreatment OutcomeDiskectomy

Stichwörter der Autor:innen

Caspar retractorPrestige LPcervical disc arthroplastycervical spineimplant height

Autor:innen und Institutionen

  • Department of Orthopedic Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan, China.

ORCID-Profile: Xiaoqiang Zhao, Xiao Yang, Shihao Chen, Hao Liu, Beiyu Wang

Förderung

  • 1·3·5 project for disciplines of excellence, West China Hospital, Sichuan University

Zitieren

APA

Zhao, X., Yang, X., Yao, M., Huang, K., Wu, T., Chen, S., Deng, Y., Liu, H., & Wang, B. (2026). Effect of Keeping Caspar Retractor During Prestige LP Cervical Disc Implantation on Intra‐ and Postoperative Outcomes. Orthopaedic Surgery, 18(11), 2428-2439. https://doi.org/10.1111/os.70438

Vancouver

Zhao X, Yang X, Yao M, Huang K, Wu T, Chen S, et al. Effect of Keeping Caspar Retractor During Prestige LP Cervical Disc Implantation on Intra‐ and Postoperative Outcomes. Orthopaedic Surgery. 2026;18(11):2428-2439. doi:10.1111/os.70438

BibTeX
@article{Zhao2026,
  author = {Zhao, Xiaoqiang and Yang, Xiao and Yao, Minghe and Huang, Kangkang and Wu, Tingkui and Chen, Shihao and Deng, Yi and Liu, Hao and Wang, Beiyu},
  title = {Effect of Keeping Caspar Retractor During Prestige LP Cervical Disc Implantation on Intra‐ and Postoperative Outcomes},
  journal = {Orthopaedic Surgery},
  year = {2026},
  volume = {18},
  number = {11},
  pages = {2428--2439},
  doi = {10.1111/os.70438}
}
Kostenlos starten →