Development and Validation of an AI ‐Integrated System for Automated Fracture Detection and Pedicle Puncture Planning in Lumbar Osteoporotic Vertebral Compression Fractures Based on the Nine‐Grid Area Division Method
Orthopaedic Surgery · 2026-06 · 18 (6) · 1266-1277
DOI: 10.1111/os.70344 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Orthopaedic Surgery, online erschienen am 13.05.2026. Verfasst von Weiyang Zuo und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics, Beijing Friendship Hospital, Capital Medical University, Beijing, China. Hauptthemen laut MEDLINE: Lumbar Vertebrae, Spinal Fractures, Fractures, Compression, Osteoporotic Fractures. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Capital Health Research and Development of Special Fund, Beijing Municipal Natural Science Foundation-Haidian Incubation Project, Tongzhou District Science and Technology Program of Beijing Municipality.
Abstract (Originalsprache)
Objective
The clinical application of the Nine‐grid Area Division Method for pedicle puncture in L‐OVCF is limited by high technical thresholds and low efficiency. This study aimed to develop an AI‐integrated automated system for L‐OVCF diagnosis and pedicle puncture planning by combining the nine‐grid method with deep learning, and to validate its diagnostic accuracy, planning consistency, and clinical application efficiency.
Methods
A multicenter CT dataset of L‐OVCF patients was collected from three hospitals affiliated with Capital Medical University (January 2020–December 2022). A two‐stage improved U‐Net architecture was constructed for automated lumbar vertebral segmentation, and a 3D ResNet50 network was used for L‐OVCF identification. A geometric algorithm was developed to realize automated puncture path planning based on the Nine‐grid Area Division Method. The performance of the segmentation and diagnosis modules was evaluated with DSC, AUC, and Hausdorff Distance. 20 cases were randomly selected to compare the consistency of puncture planning between the AI system and senior surgeons' manual planning, and the planning efficiency and resource consumption of the two methods were analyzed.
Results
The proposed two‐stage U‐Net achieved an overall DSC of 0.934 for vertebral segmentation, significantly outperforming the single‐stage nnU‐Net model. The L‐OVCF identification model yielded a high degree of accuracy with AUC of 0.918 (95% CI: 0.885–0.925). The automated planning results showed extremely high consistency with manual planning (DSC = 0.958, IoU = 0.921, HD = 486.7 μm), and the planning efficiency was significantly improved with memory consumption within the capacity of standard clinical workstations.
Conclusions
The developed AI‐integrated system accurately reproduces the preoperative planning logic of senior surgeons, with high diagnostic accuracy and puncture planning consistency, while markedly improving planning efficiency and reducing the technical threshold of the nine‐grid method. It has good clinical translational potential and can provide a reliable auxiliary tool for the precise and minimally invasive treatment of L‐OVCF.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedics, Beijing Friendship Hospital, Capital Medical University, Beijing, China.
- Longwood Valley Medical Technology Co Ltd, Beijing, China.
- Department of Orthopedics, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China.
- Department of Spine Surgery, Beijing Shijitan Hospital, Capital Medical University, Beijing, China.
ORCID-Profile: Lixiang Ding
Förderung
- Capital Health Research and Development of Special Fund
- Beijing Municipal Natural Science Foundation-Haidian Incubation Project
- Tongzhou District Science and Technology Program of Beijing Municipality
Zitieren
APA
Zuo, W., Xie, Y., Meng, H., Liu, D., Yuan, S., Song, J., Lei, X., Liu, X., Zhang, Y., Zang, L., Ding, L., Zhang, L., & Fei, Q. (2026). Development and Validation of an AI ‐Integrated System for Automated Fracture Detection and Pedicle Puncture Planning in Lumbar Osteoporotic Vertebral Compression Fractures Based on the Nine‐Grid Area Division Method. Orthopaedic Surgery, 18(6), 1266-1277. https://doi.org/10.1111/os.70344
Vancouver
Zuo W, Xie Y, Meng H, Liu D, Yuan S, Song J, et al. Development and Validation of an AI ‐Integrated System for Automated Fracture Detection and Pedicle Puncture Planning in Lumbar Osteoporotic Vertebral Compression Fractures Based on the Nine‐Grid Area Division Method. Orthopaedic Surgery. 2026;18(6):1266-1277. doi:10.1111/os.70344
BibTeX
@article{Zuo2026,
author = {Zuo, Weiyang and Xie, Yu and Meng, Hai and Liu, Dong and Yuan, Shuo and Song, Jipeng and Lei, Xiaoda and Liu, Xingyu and Zhang, Yafang and Zang, Lei and Ding, Lixiang and Zhang, Lingyi and Fei, Qi},
title = {Development and Validation of an AI ‐Integrated System for Automated Fracture Detection and Pedicle Puncture Planning in Lumbar Osteoporotic Vertebral Compression Fractures Based on the Nine‐Grid Area Division Method},
journal = {Orthopaedic Surgery},
year = {2026},
volume = {18},
number = {6},
pages = {1266--1277},
doi = {10.1111/os.70344}
}
EUVIMED