EUVIMEDEUVIMED entdecken
FallberichtÜbersichtsarbeitOpen Access · CC BY-NC-ND 4.0

Robotic‐Assisted Partial Revision of Total Knee Arthroplasty: First Case Report and Literature Review

Xinguang Wang, Kangpeng Li, Ziyang Dong, Zhencan Han, Yipu Zhang, Yang Li, Zijian Li, Hua Tian iD

Orthopaedic Surgery · 2026-07 · 18 (7) · 1529-1541

DOI: 10.1111/os.70343 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Orthopaedic Surgery, online erschienen am 22.05.2026. Verfasst von Xinguang Wang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics, Peking University Third Hospital, Beijing, China. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Reoperation, Robotic Surgical Procedures. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Beijing Municipal Commission of Science and Technology, Pharmaceutical Innovation varieties and platform cultivation project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Revision total knee arthroplasty (rTKA) poses substantial technical challenges. Although robotic assistance has demonstrated efficacy in primary TKA, its application in partial revision procedures remains poorly understood. This study presents a case of robotic‐assisted partial rTKA—specifically, isolated tibial component revision using the retained femoral component as a registration reference—and provides a comprehensive review of the current literature. Case Presentation A 66‐year‐old male presented with progressive knee pain 8 years after left TKA. Imaging revealed a well‐fixed femoral component but isolated aseptic loosening with posterior tilting of the tibial component. Given the stability of the femoral component, a robotic‐assisted partial revision targeting only the tibial component was performed. The robotic system was registered intraoperatively using the well‐fixed retained femoral component as the primary reference, enabling accurate spatial orientation despite the altered tibial anatomy. A critical prerequisite for this procedure was implant compatibility between the retained Triathlon femoral component and the planned Triathlon TS revision system. After removal of the loose tibial tray and debridement, robotic‐arm guidance was used for precise tibial osteotomy with a 10 mm augment. Postoperative imaging confirmed optimal component positioning. The patient achieved 0°–130° range of motion within 2 weeks, with favorable short‐term clinical and radiological outcomes at 1 year follow‐up.

Conclusion

This case demonstrates the technical feasibility of robotic‐assisted partial TKA revision, with favorable short‐term clinical and radiological outcomes at 1 year follow‐up. The technique enabled precise osteotomy, balanced gap restoration, and preservation of the well‐fixed femoral component. While these preliminary results are encouraging, larger studies with longer follow‐up are needed to establish comparative effectiveness and generalizability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeReoperationRobotic Surgical ProceduresHumansAgedMaleProsthesis FailureKnee ProsthesisTibia

Stichwörter der Autor:innen

knee arthroplastypartial revisionrobot

Autor:innen und Institutionen

  • Department of Orthopedics, Peking University Third Hospital, Beijing, China.
  • Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, China.

ORCID-Profile: Hua Tian

Förderung

  • Beijing Municipal Commission of Science and Technology, Pharmaceutical Innovation varieties and platform cultivation project

Zitieren

APA

Wang, X., Li, K., Dong, Z., Han, Z., Zhang, Y., Li, Y., Li, Z., & Tian, H. (2026). Robotic‐Assisted Partial Revision of Total Knee Arthroplasty: First Case Report and Literature Review. Orthopaedic Surgery, 18(7), 1529-1541. https://doi.org/10.1111/os.70343

Vancouver

Wang X, Li K, Dong Z, Han Z, Zhang Y, Li Y, et al. Robotic‐Assisted Partial Revision of Total Knee Arthroplasty: First Case Report and Literature Review. Orthopaedic Surgery. 2026;18(7):1529-1541. doi:10.1111/os.70343

BibTeX
@article{Wang2026,
  author = {Wang, Xinguang and Li, Kangpeng and Dong, Ziyang and Han, Zhencan and Zhang, Yipu and Li, Yang and Li, Zijian and Tian, Hua},
  title = {Robotic‐Assisted Partial Revision of Total Knee Arthroplasty: First Case Report and Literature Review},
  journal = {Orthopaedic Surgery},
  year = {2026},
  volume = {18},
  number = {7},
  pages = {1529--1541},
  doi = {10.1111/os.70343}
}
Kostenlos starten →